E R R O R C O D E S
®
COMBITHERM
ERROR CODES A ND R EASONS (con tinued)
Error | Display Show s | When doe s the erro r occu r? | Possible reason |
Code |
|
|
|
|
|
|
|
E29 | Probe Short to Frame | Activated if one or more of the temperature | • Connection issue at any of the temperature |
|
| sensors were connected to GND for 5 | sensors. |
|
| seconds. | • Temperature sensor shorted to |
|
|
| |
|
|
| ground/faulty. |
|
|
|
|
E34 | DE (Drain) Pump Failure | Activated if water level did not drop below the | • Problem with water level probe. |
|
| low level sensor in the generator during a | • Scale |
|
| steam generator flush. | |
|
|
| |
|
|
| • Scale plugging drain pump. |
|
|
| • Faulty drain pump. |
|
|
|
|
E35 | Venting Error | Activated when vent switch reads open (vent | • Alignment issue between motor cam and |
|
| closed) when it should be closed (vent open), | micro switch. |
|
| or when it reads closed (vent open) when it | • Connection issue at micro switch. |
|
| should be open (vent closed). | |
|
|
| |
|
|
| • Connection issue at control. |
|
|
| • Faulty vent switch. |
|
|
| • Faulty vent motor. |
|
|
|
|
E36 | Steam Temp High | Activated when oven temperature probe | • Water supply is shut off while unit is running |
|
| measures a temperature in excess of 395°F | in Steam or Combi mode. |
|
| when running in Steam or Combi mode. | • Plugged or faulty |
|
|
| |
|
|
| • Obstruction between |
|
|
| water inlet. |
|
|
|
|
E80 | ID Error | Control is unable to detect whether unit is gas | • Connection issue at |
|
| or electric. | • Faulty control. |
|
|
| |
|
|
|
|
E81 | Program Memory Error | Temperature value or time value of a program | • Program was generated in °C and control has |
|
| step is not allowed. | been switched to °F. |
|
|
| • Program was generated in °F and control has |
|
|
| been switched to °C. |
|
|
|
|
E82 | WP Error | Temperature value or time value of current | • Delete program and reinstall. |
|
| cooking algorithm is out of allowed array. |
|
|
|
|
|
E83 | Algo Error | Cooking algorithm sent by operating module | • Software versions of control unit and |
|
| (BM) is unknown to control unit (SM). | operating module are incompatible. |
|
|
| • Software error in operating module. |
|
|
|
|
E96 | Connection Error | No or bad communication between control | • Connection issue at ribbon cable on display |
|
| unit (SM) and operating module (BM). | or relay board. |
|
|
| • Faulty ribbon cable. |
|
|
| • Software versions of control unit and |
|
|
| operating module are incompatible. |
|
|
|
|
ELECTRIC COMBITHERM — INSTALLA TI ON MANU AL