1 0 • 1 8 ES S P E C I F I C A T I O N S

1 0 • 1 8 ES S P E C I F I C A T I O N S

®

 

COMBITHERM

 

 

 

 

 

 

 

 

 

30"

 

 

 

 

43-7/8"

 

42-13/16"

 

 

 

4-11/16" (120mm)

(760mm)

 

 

 

(1114mm)

 

(1087mm)

 

 

 

Decalcification

Water Drain

 

41-15/16"

 

40-1/8"

 

 

 

 

2-5/16" (58mm)

 

 

 

 

 

 

(Side Back)

 

(1064mm)

 

 

 

 

 

Port

 

 

 

(1019mm)

 

 

3/8"-22 (568mm) 1/2"-15 (393mm)

3/4"-12 (323mm)

 

 

 

(1761mm)

 

(192mm)9/16"-7 7/8"-32 (834mm) (1026mm)7/16"-40

 

 

 

(Bottom)

 

Steam

 

(158mm)1/4"-6

 

 

 

 

 

 

 

Untreated Water

Vents

 

 

 

 

 

 

 

 

 

 

 

(Top)

 

 

 

 

 

 

 

 

 

 

 

Intake (Bottom)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Treated Water

 

 

 

 

 

 

 

 

 

 

 

 

 

Intake (Bottom)

 

 

 

 

Water Drain

 

 

 

 

 

 

Electrical Connection

 

 

 

 

(Bottom)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/8"

 

 

25-5/8"

 

 

 

 

 

 

 

 

 

 

 

69-

33-1/8"

4-15/16"

(650mm)

 

 

 

 

 

 

 

 

 

 

 

8-11/16"

 

 

 

 

 

 

 

 

 

 

 

 

(840mm)

(125mm)

 

 

 

 

 

 

 

 

 

 

 

 

(219mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2" (50mm)

 

 

 

 

 

 

 

 

 

 

 

 

46-7/8" (1190mm)

 

 

DIME NS IONS : H x W x D

 

 

 

 

 

 

 

 

 

 

 

 

 

(10 26mm x 1114mm x 1087mm)

 

 

 

 

 

 

 

 

 

 

 

40-7/1 6" x 43-7/ 8" x 4 2-13/16"

IN ST ALL ATI ON REQUIREMENTS

 

 

 

EXTERIOR:

 

 

 

 

 

 

EXTERIOR WITH RETRACTABLE DOOR:

 

 

Ove n must be installed le vel.

 

 

 

 

 

(10 26mm x 1216mm x 10 87mm)

Hood installa tion is r equired.

 

 

 

 

 

40-7/1 6" x 47-7/ 8" x 4 2-13/16"

Water sup

ply sh ut-off valve an d back-f low

 

INTERIOR:

 

(781mm x 596mm x 722mm)

preve nter .

 

 

 

 

 

 

 

 

30-3/ 4" x 2 3-1 /2" x 28-7 /16"

 

TWO (2) COLD WATER INLETS - DRINKING QUALITY

USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S

WATER REQUIREMENTS

 

 

 

 

 

 

WAT ER QU ALIT Y MIN IM UM ST ANDARDS

ONE (1) TREATED WATER INLET:

3/4" NPT*

 

 

MINIMUM WATER QUALITY STANDARDS WILL VOID THIS

ONE (1) UNTREATED WATER INLET:

 

 

WARRANTY. It is the responsibility of the purchaser to ensure that

LINE PRESSURE:

 

 

3/4" NPT*

2.8 to 6.2 bar

incoming water supply is compliant with the specifications listed

 

 

 

 

 

 

30 to 90 psi

through adequate treatment measures. Installation of the

 

 

 

WATER DRAIN: 1-1/2"

CONNECTION WITH AIR GAP

CombiGuard™ Water Filtration System is recommended, but this

* Can manifold off of one 3/4" line.

 

 

 

 

 

Contaminant

Inlet Water Requirements (untreated water)

 

 

 

 

 

 

 

 

 

 

 

 

system may not address all water quality issues present.

CLEARA NCE REQUIREMENTS

 

 

 

 

Free Chlorine

Less than 0.1 ppm (mg/L)

 

 

LEF T

: 6" (152mm)

PLUS SERVICE ACCESS :

18" (457mm)

RECOMMENDE D

Hardness

Less than 3 gpg (52 ppm)

 

 

 

FRO M HEA T PRO DU CI NG EQU IPM ENT

Chloride

Less than 30 ppm (mg/L)

 

 

 

20" (508mm)

TO P: 20" (508mm) FOR AIR MOVEMENT

pH

7.0 to 8.5

 

 

RI GHT

: 4" (102mm)

Alkalinity

Less than 50 ppm (mg/L)

 

 

BACK

: 4" (102mm)

BO TTOM : 5 -1/ 8"

(13 0mm)

FOR LEGS

Silica

Less than 12 ppm (mg/L)

 

COUNTER-TOP INSTALLATIONS MUST MAINTAIN 4" (102mm)

MINIMUM

Total Dissolved

Less than 60 ppm

 

CLEARANCE

FROM COUNT ER SUR FACE.

 

 

 

 

Solids (tds)

 

ELEC TRICA L

 

 

 

 

 

 

 

 

 

 

 

 

VOLTAGE

 

PHASE

 

CYCLE/HZ

 

AWG

AMPS

kW

-240

at 208

 

3

 

 

50/60

 

3 Wire plus ground

61.3 /ph

22.0

208

at 240

 

 

 

 

 

 

 

AWG 2

70.0 /ph

29.2

-415

at 380

 

3

 

 

50/60

 

4 Wire plus ground

33.5 /ph

22.0

380

at 415

 

 

 

 

 

 

 

AWG 6

40.7 /ph

29.2

-480

at 440

 

3*

 

 

50/60

 

3 Wire plus ground

36.0 /ph

27.2

440

at 480

 

 

 

 

 

 

 

AWG 6

43.5 /ph

36.1

 

 

 

* ELECT RICAL SERVICE CHARGE APP LIES

 

 

 

WEI GHT

 

 

 

CAP ACI TY

 

 

 

522 lb

(237 k g)

 

FULL-SIZE PANS:

20" x 12" x 2-1/2"

Twenty (20)

NET

 

GN 1/1:

530 x 325 x 65mm

Twenty (20)

 

 

 

 

GN 2/1:

650 x 530 x 65mm

Ten (10)

 

646 lb

(293 k g)

 

SHI P

 

FULL-SIZE SHEET PANS:*

18" x 26" x 1"

Ten (10)

CRATE

46" X 51"

X 46" EST.

 

ON WIRE SHELVES ONLY

240 lb ( 109 k g) MAX IM UM

 

 

 

 

 

 

 

DIMENSIO NS:

(1168 x 1 295 x 1168m m)

 

VO LUME MAXI MUM : 150 QUARTS (190 LITE RS )

 

 

 

 

*AD DITION AL WIRE SH ELVES RE QUIRE D FOR MAXIM UM CAPAC ITY

 

 

 

 

 

 

 

 

ELE CTRIC COMBITHERM INST ALLAT ION MANUAL #MN -286 77

 

PG. 12

 

 

 

 

 

 

Page 14
Image 14
Alto-Shaam 10.18 1 0 1 8 ES S P E C I F I C A T I O N S, DIME NS IONS H x W x D, In St All Ati On Requirements, Wei Ght