Alto-Shaam 7.14, VHes-10 E R R O R C O D E S, Cont Ro L Reset, Se Rvice Mode An, D Er Ro R Co Des

Models: 20.20 7.14 10.10 10.18 VHes-5 VHes-10

1 36
Download 36 pages 33.23 Kb
Page 28
Image 28
E R R O R C O D E S

E R R O R C O D E S

CONT RO L RESET

®

COMBITHERM

There i s a remote

possi bi li ty i n the day-

lo ck or freez e. If thi

s oc curs, the control i

to -day op erat ion of the Co mbit herm that the cont rol co uld s easy to rese t.

PRESS AN D HOLD THE POW ER K EY FOR A PERIOD OF 5 SECONDS.

Release the

POWER KEY .

The control

will w ill re set itse lf within appr oxima tely 15 se conds.

WHEN RESET, THE DISPLAY WILL INDICATE THE TIME AND DATE AND THE CONTROLS WILL BE FULLY FUNCTIONAL.

SE RVICE MODE AN

D ER RO R CO DES

 

 

Whe n t he o ven malfu nct ions, an er ror co de will appear in the display.

PRES S THE START K EY TO A CKNOWLEDGE TH E E RROR.

The k eys th at begin to flas h re present operat ional modes that are s till usable. Ref er to Emergen cy Ope ratio n.

Whe n t he o ven fault is co rrected , the Combitherm wi ll ret urn to normal Operation.

ERROR CODES A ND R EASONS

Error

Display Sh ows

 

When doe s the erro r occu r?

Possible reason

Code

 

 

 

 

 

 

 

 

 

E01

Low Water

 

ES units only:

• Water supply is shut off.

 

 

 

• Activated if running in any mode and the

• Low water pressure.

 

 

 

water level drops below the low level sensor.

 

 

 

 

 

 

 

• Activated if not in running mode and the

• Steam generator drain cap is off or loose.

 

 

 

 

 

 

 

water level drops below the low level sensor

• Drain pump is not sealing.

 

 

 

for 3 minutes.

• Faulty or scaled water level probe.

 

 

 

 

 

 

 

 

• Faulty or plugged solenoid valve assembly.

 

 

 

 

• Wiring or connection issue.

 

 

 

 

 

E02

Control Temp High

 

Activated if the temperature of the electrical

• Cooling fan not operating.

 

 

 

control is higher than 176°F for 20 seconds.

• Unit is next to a heat producing source (there

 

 

 

 

 

 

 

 

is less than 20" clearance for the control

 

 

 

 

side).

 

 

 

 

• Exhaust hood is not operating (if applicable).

 

 

 

 

 

E03

Fan Malfunction

 

Activated if the motor protection switch is

• Motor rotation is backwards.

 

 

 

tripped.

• Incorrect power to the unit.

 

 

 

 

 

 

 

 

• Connection problem at X-7 plug on relay

 

 

 

 

board pins 3-4.

 

 

 

 

 

E04

Aux Fan Fault

 

Auxiliary fan malfunction.

• Control setup programming error.

 

 

 

 

• Contact factory.

 

 

 

 

 

E11

Excess Oven Temp

 

Activated if the oven cavity temperature is

• Connection issue with oven temperature

 

 

 

higher than 518°F for 25 seconds.

sensor.

 

 

 

 

• Convection element contactor is stuck.

 

 

 

 

• Faulty oven temperature sensor.

 

 

 

 

 

 

 

ELECTRIC COMBITHERM INSTALLA TI ON MANU AL #MN-28 677

PG. 26

 

 

 

 

Page 28
Image 28
Alto-Shaam 7.14, VHes-10, VHes-5, 10.18, 10.10, 20.20 E R R O R C O D E S, Cont Ro L Reset, Se Rvice Mode An, D Er Ro R Co Des