E R R O R C O D E S
CONT RO L RESET
®
COMBITHERM
There i s a remote | possi bi li ty i n the day- |
lo ck or freez e. If thi | s oc curs, the control i |
to
PRESS AN D HOLD THE POW ER K EY FOR A PERIOD OF 5 SECONDS.
Release the | POWER KEY . |
The control | will w ill re set itse lf within appr oxima tely 15 se conds. |
WHEN RESET, THE DISPLAY WILL INDICATE THE TIME AND DATE AND THE CONTROLS WILL BE FULLY FUNCTIONAL.
SE RVICE MODE AN | D ER RO R CO DES |
|
|
Whe n t he o ven malfu nct ions, an er ror co de will appear in the display.
PRES S THE START K EY TO A CKNOWLEDGE TH E E RROR.
The k eys th at begin to flas h re present operat ional modes that are s till usable. Ref er to Emergen cy Ope ratio n.
Whe n t he o ven fault is co rrected , the Combitherm wi ll ret urn to normal Operation.
ERROR CODES A ND R EASONS
Error | Display Sh ows |
| When doe s the erro r occu r? | Possible reason |
Code |
|
|
|
|
|
|
|
|
|
E01 | Low Water |
| ES units only: | • Water supply is shut off. |
|
|
| • Activated if running in any mode and the | • Low water pressure. |
|
|
| water level drops below the low level sensor. | |
|
|
|
| |
|
|
| • Activated if not in running mode and the | • Steam generator drain cap is off or loose. |
|
|
|
| |
|
|
| water level drops below the low level sensor | • Drain pump is not sealing. |
|
|
| for 3 minutes. | • Faulty or scaled water level probe. |
|
|
|
| |
|
|
|
| • Faulty or plugged solenoid valve assembly. |
|
|
|
| • Wiring or connection issue. |
|
|
|
|
|
E02 | Control Temp High |
| Activated if the temperature of the electrical | • Cooling fan not operating. |
|
|
| control is higher than 176°F for 20 seconds. | • Unit is next to a heat producing source (there |
|
|
|
| |
|
|
|
| is less than 20" clearance for the control |
|
|
|
| side). |
|
|
|
| • Exhaust hood is not operating (if applicable). |
|
|
|
|
|
E03 | Fan Malfunction |
| Activated if the motor protection switch is | • Motor rotation is backwards. |
|
|
| tripped. | • Incorrect power to the unit. |
|
|
|
| |
|
|
|
| • Connection problem at |
|
|
|
| board pins |
|
|
|
|
|
E04 | Aux Fan Fault |
| Auxiliary fan malfunction. | • Control setup programming error. |
|
|
|
| • Contact factory. |
|
|
|
|
|
E11 | Excess Oven Temp |
| Activated if the oven cavity temperature is | • Connection issue with oven temperature |
|
|
| higher than 518°F for 25 seconds. | sensor. |
|
|
|
| • Convection element contactor is stuck. |
|
|
|
| • Faulty oven temperature sensor. |
|
|
|
|
|
|
| ELECTRIC COMBITHERM — INSTALLA TI ON MANU AL | ||