WATER R EQU IREM ENTS

WAT E R S U P P LY & I N S TA L L AT I O N R E Q U I R E M E N T S

®

WATER R EQU IREM ENTS
TWO (2) COLD WATER INLETS - DRI KING QUALITY

ONE (1)

TREATED WATER INLET:

3/4" NPT*

ONE (1)

UNTREATED WATER INLET:

3/4" NPT*

* Can manifold off of one 3/4" line

2.8 to 6.2 bar

LINE PRESSURE:

30 to 90 psi

REFER TO PUBLISHED SPECIFIC WATER REQUIREMENTS

WATER DRAIN: 1-1/2"CONNECTION WITH AIR GAP

COMBITHERM

Flush the wa ter line at th e in stallat ion s ite be fore connect ing the oven to the water suppl y. A hose conne ctor is supplied for flexible hose connection to the COLD water source.

PIPE SEALING TAPE (TEFLON ®) MUST BE U SED AT

ALL CONNECTION POINTS.

The use of a pipe sealing
compo und is not recom mended .

 

Incoming cold water connection

T connection

Cold water line to untreated oven connection

ONE SUGGESTED METHOD OF INSTALLATION

Water Filter

Cold water line to

Treated cold

filter or treatment

water to treated

system

connection on oven

 

 

NOTE:

BOTH TR EATED AND UNT REATED WATER

CONN ECTIONS MUST B E CO NNE CTED FOR PROPER

OPER ATIO N O F THE OV EN. B OTH CO NNE CTIONS

CAN B E TREATED WATE R, B UT SHOULD NEVER BE

CONN ECTED TO ONLY UNT REATED WATER.

UNIONS OR FLEX IBLE L INES SHO ULD BE USE D TO

ALLOW FOR OVEN M OVE MENT WHE N BEI NG

SERV ICED OR CLEANI NG I S NEEDE D.

REFER TO DIMENSIO N DR AWINGS BEGI NNI NG O N

PAGE 4 FOR PROPER I NTAKE LOCATI ONS.

ELE CTRIC COMBITHERM INST ALLAT ION MANUAL #MN -286 77

PG. 22

Page 24
Image 24