WAT E R S U P P LY & I N S TA L L AT I O N R E Q U I R E M E N T S | ® |
TWO (2) COLD WATER INLETS - DRI KING QUALITY | ||
ONE (1) | TREATED WATER INLET: | 3/4" NPT* |
ONE (1) | UNTREATED WATER INLET: | 3/4" NPT* |
* Can manifold off of one 3/4" line | 2.8 to 6.2 bar | |
LINE PRESSURE: | 30 to 90 psi |
REFER TO PUBLISHED SPECIFIC WATER REQUIREMENTS
WATER DRAIN:
COMBITHERM
Flush the wa ter line at th e in stallat ion s ite be fore connect ing the oven to the water suppl y. A hose conne ctor is supplied for flexible hose connection to the COLD water source.
PIPE SEALING TAPE (TEFLON ®) MUST BE U SED AT | |
ALL CONNECTION POINTS. | The use of a pipe sealing |
compo und is not recom mended . |
|
Incoming cold water connection
T connection
Cold water line to untreated oven connection
ONE SUGGESTED METHOD OF INSTALLATION
Water Filter
Cold water line to | Treated cold |
filter or treatment | water to treated |
system | connection on oven |
|
|
NOTE:
BOTH TR EATED AND UNT REATED WATER
CONN ECTIONS MUST B E CO NNE CTED FOR PROPER
OPER ATIO N O F THE OV EN. B OTH CO NNE CTIONS
CAN B E TREATED WATE R, B UT SHOULD NEVER BE
CONN ECTED TO ONLY UNT REATED WATER.
UNIONS OR FLEX IBLE L INES SHO ULD BE USE D TO
ALLOW FOR OVEN M OVE MENT WHE N BEI NG
SERV ICED OR CLEANI NG I S NEEDE D.
REFER TO DIMENSIO N DR AWINGS BEGI NNI NG O N
PAGE 4 FOR PROPER I NTAKE LOCATI ONS.