Alto-Shaam 20.20, VHes-10, VHes-5, 10.18 E R R O R C O D E S, ERROR CODE S AND R EASONS contin ued

Models: 20.20 7.14 10.10 10.18 VHes-5 VHes-10

1 36
Download 36 pages 33.23 Kb
Page 29
Image 29
ERROR CODE S AND R EASONS (contin ued)

®

COMBITHERM

E R R O R C O D E S

ERROR CODE S AND R EASONS (contin ued)

Error

Display Sho ws

When doe s the erro r occu r?

Possible reason

Code

 

 

 

 

 

 

 

E13

Excess Steam Gen Temp

ES units only:

• Problem with water level probe.

 

 

Activated if the temperature of the steam

• Scale build-up inside steam generator.

 

 

generator probe (B-4) is higher than 248°F

 

 

 

 

 

for 26 seconds.

• Steam element contactor is stuck.

 

 

 

• Connection issue with B-4 probe.

 

 

 

• Faulty B-4 probe.

 

 

ESi units only:

• Jumper on X-3 is improperly positioned.

 

 

Activated if the position of personality jumper

Should be between 2-8 or, if it is a smoker,

 

 

on X-3 is incorrect.

between 2-9.

 

 

Activated if the position of B-4 jumper is

• Jumper on X-6a is improperly positioned.

 

 

incorrect.

Should be between 13-14.

 

 

 

 

E15

Excess Condensate Temp

Activated if the temperature of the condensate

• Water supply is shut off.

 

 

probe (B-3) is higher than 212°F for 26

• Faulty or plugged solenoid valve (Y-2).

 

 

seconds.

 

 

 

 

 

 

• Connection issue at B-3 probe.

 

 

 

• Faulty B-3 probe.

 

 

 

 

E21

Oven Probe Fault

Activated if oven temperature probe (N-6) is

• Connection issue at N-6 probe.

 

 

interrupted.

• Faulty N-6 probe.

 

 

 

 

 

 

 

E22

Core Temp Probe Fault

Activated if cooking in Core Temp mode and

• CTC sensor is damaged.

 

 

the CTC sensor measures an excessive

4-point CTC sensor is activated, but 1-point

 

 

temperature.

 

 

CTC sensor is installed.

 

 

 

 

 

 

• Cable connection of CTC sensor is damaged.

 

 

 

• Hardware problem on control unit (SM).

 

 

 

 

E23

Steam Gen Probe Fault

ES units only:

• Connection issue at B-4 probe.

 

 

Activated if the steam generator probe (B-4) is

• Faulty B-4 probe.

 

 

interrupted.

 

 

 

 

 

ESi units only:

• Jumper on X-3 is imperly positioned.

 

 

Should be between 2-8 or, if it is a smoker,

 

 

• Activated if the position of personality

 

 

between 2-9.

 

 

jumper on X-3 is incorrect.

 

 

 

 

 

• Activated if the position of B-4 jumper is

• Jumper on X-6a is improperly positioned.

 

 

Should be between 13-14.

 

 

incorrect.

 

 

 

E24

Bypass Probe Fault

Activated if the bypass probe (B-5) is

• Connection issue at B-5 probe.

 

 

interrupted.

• Faulty B-5 probe.

 

 

 

 

 

 

 

E25

Condensate Probe Fault

Activated if the condensate probe (B-3) is

• Connection issue at B-3 probe.

 

 

interrupted.

• Faulty B-3 probe.

 

 

 

 

 

 

 

E26

Steam Gen Safety Probe

Activated if the steam generator safety probe

• Connection issue at N-8 probe.

 

Fault

(N-8) is interrupted.

• Faulty N-8 probe.

 

 

 

 

 

 

 

E27

Excess Steam Gen Safety

Activated if the steam generator safety probe

• Problem with water level probe.

 

Temp

(N-8) measures a temperature in excess of

• Scale build-up inside steam generator.

 

 

266°F.

• Steam element contactor is stuck.

 

 

 

• Connection issue with N-8 probe.

 

 

 

• Faulty N-8 probe.

 

 

ESi units only:

• Jumper on X-6b is improperly positioned.

 

 

• Activated if the position of N-8 jumper is

Should be between 1-2.

 

 

incorrect.

 

 

 

 

 

ELECTRI C COMB ITHERM INSTALLA TION MANU AL #MN -286 77

PG . 27

Page 29
Image 29
Alto-Shaam 20.20, VHes-10, VHes-5, 10.18, 10.10, 7.14 manual E R R O R C O D E S, ERROR CODE S AND R EASONS contin ued