This document
This document contains the safety information relevant for the appliance along with a quick reference guide.
Prior to using the appliance for the first time, be sure to read this docu- ment through and keep it ready to
hand.
Further support
Detailed information on the appliance can be found in the operating instructions, which you can download from our web site at
For further queries, please contact the Nilfisk- Alto service representative responsible for your country. See reverse of this document.
Important safety instructions
Symbols used to mark instructions
DANGER
Danger that leads directly to seri- ous or irreversible injuries, or even death.
WARNING
Danger that can lead to serious injuries or even death.
CAUTION
Danger that can lead to minor injuries and damage.
The appliance must
•only be used by persons, who have been instructed in its correct usage and explicitly commissioned with the task of operating it
•only be operated under supervision
•not be used by children
Before starting work, the operating staff must be informed on
•use of the vacuum cleaner
•risks associated with the material to be picked up
•safe disposal of the picked up material
ATTIX
1.Do not use any unsafe work techniques.
2.Never use the vacuum cleaner without a filter.
3.Switch off the appliance and disconnect the mains plug in the following situations:
Besides the operating instructions and the binding accident prevention regulations valid in the country of use, observe recognised regulations for safety and proper use.
Purpose and intended use
Since 1997, there is a new division of hazardous dusts and their assigned vacuum machines. These are regulated by IEC 60335-
Dust Class M (medium). The dusts
which belong to this class are: dusts
with OEL values1) > 0.1 mg/m³ as well as saw dust. The machine is tested in its entirety by vacuums for this dust class. The maximum degree of permeability is 0.1% and the disposal must be low dust.
Dust Class H (high). The dusts which
belong to this class are: dusts with
OEL values1), all carcinogenic dusts and dusts which are mixed with pathogenic agents. Vacuums for Dust Class H are tested in their entirety and have a maximum degree of permeability of 0.005%. The disposal must be dust free.
These vacuums may be used for picking up dusts from the Dust Classes L, M and H as well as ex- plosive dusts which makes a Series
Type 22 vacuum necessary. Included in these classes are
The air flow in safety vacuum systems has to be strictly controlled to achieve a minimum flow rate of Vmin = 20 m/s in the suction hose.