Nilfisk-ALTO Nilfisk C 100.4 user manual Mains power connection, Safety devices, Thermal sensor

Models: C 110.2 X-TRA Nilfisk C 100.4

1 18
Download 18 pages 30.96 Kb
Page 4
Image 4
Mains power connection

safety only use original spare parts from the manufacturer or approved by the manufac- turer.

High pressure hoses, fi ttings and couplings are important for the safety of the appli- ance. Only use hoses, fi ttings and couplings recommended by the manufacturer.

Do not use the appliance if a supply cord or impor- tant parts of appliance are damaged, e.g. safety device , high pressure hose and trig- ger gun.

The appliance is intended to clean cars and garden etc.. Appropriate ear protection has to be used.

Never use the machine in an environment where there could be a danger of explo- sion. If any doubt arises, please contact the local authorities.

It is not allowed to clean as- bestos-containing surfaces with high pressure.

This high pressure washer must not be used at tempera- tures below 0°C.

WARNING!

Inadequate extension cables can be dangerous. Cables on drums should always be com- pletely unwinded to prevent the cable from overheating.

If an extension cable is used, the plug and the socket must be waterproof and comply with the below-mentioned requirements for length and cable dimen- sions.

1.0 mm²

max.

12.5 m

1.5 mm²

max.

20 m

2.5 mm²

max.

30 m

If the electric cable is damaged, it must be re- placed by the manufacturer or his service agent or simi- larly qualifi ed person in order to avoid a hazard.

Mains power connection

The following should be ob- served when connecting the high pressure washer to the electric installation:

The electric installation shall be made by a certifi ed elec- trician and comply with IEC 364.

It is recommended that the electric supply to this appli- ance should include either a residual current device that will interrupt the supply if the leakage current to earth ex- ceeds 30 mA for 30 ms.

Water connection Connection to the public mains according to regula- tions.

Inlet hose can be connected to the water mains with a max. inlet pressure of 10 bars.

This high pres- sure washer is

only allowed to be connected with the drinking water

mains, when an appropriate

backfl ow preventer has been installed, Type BA according to EN 1717. The backfl ow pre- venter can be ordered under number 106411177. The length of the hose between the back-

ow preventer and the high pressure washer must be at least 10 metres to absorb pos- sible pressure peaks (min diam- eter ½ inch).

Operation by suction (for ex- ample from a rainwater vessel) is carried out without backfl ow preventer. Recommended suc- tion set: 126411387.

As soon as water has fl own through the BA valve, this water is not considered to be drinking water any more.

IMPORTANT! Only use wa- ter without any impurities. If there is a risk of running sands in the inlet water (i.e. from your own well), an additional fi lter should be mounted.

Safety devices

The unloader valve can re- duce pressure if it exceeds pre-set values.

Locking device on spray gun (7a) (see illustration at the end of this manual):

The spray gun features a lock- ing device. When the pawl is activated, the spray gun cannot be operated.

Thermal sensor:

A thermal sensor protects the motor against overloading. The machine will restart after a few minutes when the thermal sen- sor has cooled.

4

Page 4
Image 4
Nilfisk-ALTO Nilfisk C 100.4, C 110.2 X-TRA user manual Mains power connection, Safety devices, Thermal sensor