Norcold N81X, N61X owner manual Display Codes, Fault Codes

Models: N61X N81X

1 14
Download 14 pages 28.77 Kb
Page 12
Image 12
Display Codes

Display Codes

Light and Status

Meaning

 

 

ON light is on.

The refrigerator is operating on AC.

GAS light is off.

 

 

 

ON light is on.

The refrigerator is operating on propane gas.

GAS light is on.

Art01852

 

 

Fault Codes

Light and Status

Meaning

 

Corrective Actions

 

 

 

 

DC voltage is

Check:

 

unavailable to the

-

That the refrigerator is ON.

ON light is off

refrigerator control

-

That the battery charging equipment of the vehicle is operational.

 

panel or the

-

That the AC/DC converter is operational (if applicable).

 

refigerator is OFF.

-

See your dealer or authorized Norcold Service Center.

 

 

 

 

 

If in AUTO mode, check:

 

 

-

That the refrigerator is plugged in to a servicable outlet.

 

 

-

That the fuse or circuit breaker of the vehicle is intact.

 

No energy source is

-

That the vehicle generator is operational (if applicable).

 

In any mode, check:

 

available. AC voltage is

ON light and GAS light

not available (or the

-

That there is not air in the propane gas supply line. See "Removing air

both flash about once

refrigerator is in Manual

per second.

GAS mode), and the

 

from the propane gas supply lines" section of this manual.

 

burner did not ignite or

-

That the valve of the propane gas tank(s) is open.

 

re-ignite.

-

That the propane gas is at the correct pressure.

 

 

-

That the manual shut off valve of the refrigerator is open.

 

 

-

Reset the refrigertor by turning it OFFand then back to AUTO or

 

 

 

GAS mode.

 

 

-

See your dealer or authorized Norcold Service Center.

 

 

 

 

 

Check:

 

The burner did not

-

That there is not air in the propane gas supply line. See "Removing air

 

ignite or re-ignite.

 

from the propane gas supply lines" section of this manual.

ON light is on.

The refrigerator is in

-

That the valve of the propane gas tank(s) is open.

GAS light flashes

"gas lock-out", but AC

-

That the propane gas is at the correct pressure.

about once per second.

voltage has returned and

-

That the manual shut off valve of the refrigerator is open.

 

the refrigerator is

-

Reset the refrigertor by turning it OFF and then back to AUTO or

 

operating on AC.

 

GAS mode.

 

 

-

See your dealer or authorized Norcold Service Center.

 

 

 

 

ON light is on , but

The temperature sensor

 

 

failed. The refigerator is

This is not owner serviceable, see your dealer or authorized Norcold Service

flashes off 1 time

operating on the "Back-

Center.

about every 3 seconds.

Up Operating System".

 

 

 

 

 

 

 

 

 

ON light is on , but

The mode switch failed.

 

 

The refrigerator is

This is not owner serviceable. See your dealer or authorized Norcold Service

flashes off 2 times

operating in the last

Center

about every 3 seconds.

known mode.

 

 

 

 

 

 

 

 

 

ON light is on , but

The AC heater failed.

 

 

flashes off 3 times

The refigerator will

This is not owner serviceable. See your dealer or authorized Norcold Service

about every 3 seconds.

operate on propane

Center

GAS light is on.

gas only.

 

 

 

 

 

ON light is on, but

This is a fault within the

This is not owner serviceable. See your dealer or authorized Norcold Service

flashes off 4 times about

refrigerator controls.

Center.

every 3 seconds.

 

 

Art01583

 

 

 

 

Owner’s Manual 12

Page 12
Image 12
Norcold N81X, N61X owner manual Display Codes, Fault Codes