Troubleshooting

Troubleshooting

Indicator Lights

Power light is on. Error light is off.

Power light is off. Error light is off.

Power light is on. Error light flashes one time.

Power light is on. Error light flashes two times.

Power light is on. Error light flashes three times.

Power light is on. Error light flashes continually.

Problem

No problems.

The refrigerator/ freezer has no power.

The voltage is wrong.

The current is wrong (or fan current is wrong).

Fan speed is wrong.

The temperature is wrong.

Solution

Normal operating condition.

Check the 10 Amp glass that is located in the cigarette lighter plug body of the power cord.

Turn the refrigerator/freezer “OFF”, or choose the voltage setting again, or the voltage to the refrigerator/freezer is low.

*When using the AC/DC converter to operate the refrigerator/freezer, make sure that the Low Battery Shut-off Switch is in either position 1 or 3

Check the fan.

Ambient temperature is more than the normal operating temperature, or the refrigerator/freezer air-intake vent is obstructed.

Ambient temperature is more than the normal operating temperature, or the refrigerator/freezer air-intake vent is obstructed.