Warranty Information

At the beginning of the defrost cycle, both the outdoor condenser fan and compressor will turn off. After approximately 30 seconds, the compressor will turn on and begin to heat the outdoor coil causing the ice and snow to melt. NOTE: While the ice and snow is melting, some steam may rise from the outdoor unit as the warm coil causes the melting frost to evaporate. When defrost is completed, the outdoor fan motor will start, and the compressor will turn off again. In approximately 30 seconds the compressor will start up again and continue normal operation.

System Shutdown

Change the thermostat’s system mode to OFF and the fan mode to AUTO (See Figure 1). NOTE: The system will not operate, regardless of the temperature selector setting.

Warranty Information

A warranty certificate with full details is included with the heat pump. Carefully review these responsibilities with your dealer or service company. The manufacturer will not be responsible for any costs found necessary to correct problems due to improper setup, improper installation, adjustments, improper operating procedure on the part of the user, etc. Some specifi c examples of service calls which are not included in the limited warranty are:

1.Correcting wiring problems in the electrical circuit supplying the heat pump.

2.Resetting circuit breakers or other switches.

3.Adjusting or calibrating of thermostat.

INSTALLER INFORMATION

General Information

The installer should comply with all local codes and regulations which govern the installation of this type of equipment. Local codes and regulations take precedence over any recommendations contained in these instructions. Consult local building codes and the National Electrical Code (ANSI CI) for special installation requirements. Read the following instructions completely before performing the installation.

Some states require installation and service personneltobelicensed.Unqualifiedindividuals should not attempt to interpret these instructions or install this equipment.

This equipment contains R-410A refrigerant under high pressure. Installation or servicing should only be performed by qualifi ed trained personnel thoroughly familiar with this type equipment and related system components.

INSTALLER INFORMATION CAUTION:

This unit uses refrigerant R-410A. DO NOT under any circumstances use any other refrigerant in this unit. Use of another refrigerant will damage the unit.

Single packaged heat pumps are ready for easy and immediate installation and can be readily connected into the high static duct system of a home.This unit is completely assembled, wired, and run tested at the factory. This heat pump is designed for outdoor installation only. The only connections needed for installation are the supply and return ducts, the line voltage, and thermostat wiring.A complete heat pump system typically consists of:

Single Package Heat Pump

Home Fittings Kit

Unit Fittings Kit

2-Stage Cooling/Heating Thermostat

Use of components other than those specifi ed may invalidate ARI Certifi cation, Code Agency Listing, and limited warranty on the air conditioner.

Pre-Installation Check

Before you install this unit, the cooling load of the area to be conditioned must be calculated and a system of the proper capacity selected. It is recommended that the area to be conditioned be completely insulated and vapor sealed.

The electrical supply should be checked to determine if adequate power is available. If there is any question concerning the power supply, contact the local power company.

General Information CAUTION:

To prevent personal injury and/or equipment damage, check thermostat manufacturer’s operation of fan relay circuit when in EMER HEAT. When the thermostat system mode is in the EMER HEAT position, the thermostat must energize the fan relay when the fan mode is in the AUTO position.

Inspecting Equipment:

All units are securely packed at the time of shipment and, upon arrival, should be carefully inspected for damage. Claims for damage (apparent or concealed) should be filed immediately with the carrier.