Option settings Page 141 of 906
Circuit Card Description and Installation
QPC559, QPC560 Loop Signaling Trunk cards

Table 48 and Table 49 on page 142 list option settings for loop signaling

trunk cards.

Table 48
QPC559, QPC560 single density
Application
Single density—Unit 0/1
F30/F8 switch
123456
Outgoing ANI only:
loop pulsing off off off off off off
battery and ground pulsing off off off off on off
Other than outgoing ANI on off on off on off
Jumpers (QPC560) Units 0/1/2/3
600 ¾ resistive impedance connect pins 1 and 2