NTCK16 Generic Central Office Trunk cards Page 805 of 906
Circuit Card Description and Installation
Trunk Data BlockRespond to the prompts in LD 14 as shown:LD 14 – Trunk Data Block for NTCK16BX. (Part 1 of 2)
Prompt Response Description
REQ: NEW Define a new trunk unit.
TYPE: COT Central Office Trunk
TN Terminal Number
l s c u Format for Large System, CallSer ver 1000E,
and Media Gateway 1000E, wherel = loop,
s = shelf, c= card, u = unit
XTRK
(See note 1 on
page 806.)
XCOT Type is IPE COT
CDEN (8D) Card density is 8D (default).
SIGL LOP Loop start signaling
BTID
(See page 807.)
Xx Enter the country busy tone ID:
Tortola, Brazil = 10
Mexico = 10 or 08 (depending on CO)
Singapore = 11
Ireland = 3 or 9 (depending on CO) Kuwait,
Chile, Venezuela, Indonesia, Thailand,
Korea= 06. Argentina = 12 o r 07, Turkey = 14
SUPN (NO) YES Supervision yes (no)
STYP BTS
BAT
Busy tone supervision enabled
Loop break supervision enabled
CLS (LOL) SHL Attenuation Pads In, (Out)