TROUBLESHOOTING

SYMPTOMS

CAUSES

REMEDIES

 

 

 

The water pump will not start

The motor thermic protection is open

Check the mains voltage (+/- 5%

 

 

tolerance). Check the phases

 

 

in the plug are connected well.

 

 

 

The water pump will not enter

The no-return valve does not seal

Replace the valve or the gasket

in bypass

 

and check the pressure valve

 

 

body wear.

 

Leakage from the water system

Eliminate the leaks

 

of the gun

 

The water pump does not reach maximum pressure

Nozzle worn

Replace the nozzle

Pressure ball or adjustment housing

Replace the faulty part

worn or spring broken

 

Pressure valve gaskets worn

Replace the valve gaskets

Pistons seal gasket worn

Replace the gaskets

Nozzle holding head in position

Turn the head on high pressure

low pressure

 

Strong vibrations on the water pump

Water supply insufficient

Check the water supply flow and

 

 

the relative pressure (2÷10)

 

 

Check the water filter and clean

 

 

it if necessary

 

 

Prime the pump without the lance

 

Alien matter under a check valve

Check the valves, clean and reassemble

 

 

 

The burner will not start

Diesel filter blocked

Clean the filter

 

Diesel nozzle blocked

Clean the filter

 

Worn or broken electrodes

Replace the electrodes

 

The pressure switch remains open

Replace the pressure switch

 

Safety thermostat is open

Replace the safety thermostat

 

 

 

Anormal noise of Diesel pump

Low diesel

Fill diesel tank or work on cold water

 

 

 

No detergent suction

High viscosity of the employed

Further dilute the detergent

 

detergent

 

 

Detergent filter blocked

Clean the filter

 

 

 

- 12 -

Page 11
Image 11
North Star 157394 manual Troubleshooting, Symptoms Causes Remedies