INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

If installing the SCOUT 157596 indoors or in an enclosed area, observe the following guidelines:

-Operate the unit on a level surface to ensure proper lubrification to the water pump.

-Be certain the ambient temperature of the environment does not exceed 100°F. This ensures adequate air supply for the burner,

-Do not expose the unit to rain, snow or freezing temperatures.

-Do not install where dust, vapors or combustible materials will be present.

PRE-OPERATION CHECK

CLOTHING

Proper clothing is essential for your safety. Use whatever is necessary to protect your eyes, ears, feet and skin. Additional safely accessories (like a respiratory mask) may be required when using detergents with this washer.

PUMP

If oil is needed, fill with SAE 80-90 non-detergent oil AGIP ROTRA MULTI THT or correspondant products:

U.T.T.O. Lubricants (Universal Tractor Transmission Oil)

SHELL DONAX TD

MOBIL MOBILFLUID 422

FORD M2C-86 B - M2C-134B/C

JOHN DEERE J20A

MASSEY - FERGUSON M-1135

ESSO TORQUE FLUID 62

API GL-4

Quantity: 0,26 lb (do not overfill)

WATER SUPPLY

1.Connect the water supply to the 3/4” female garden hose swivel on the water inlet port of the unit. Connect the other end of the hose to the pressurized water supply. The supply hose should have a 3/4” inside diameter (ID) and be no longer than 50 feet.

2.The water supply pressure must be a minimum of 20 pounds per square inch (PSI) and a maximum of 125 PSI. The flow rate must be at least 3 gallons per minute (GPM).

3.Use a water softener if there is high mineral content in the water of your area. High mineral content causes excessive scale build-up in the coil/heat exchanger.

4.Un-roll the hose reel and then connect one end of the high pressure discharge hose to the water- gun assembly.

!

Be sure all connections are securely tightened.

 

 

Sudden release of high pressure streams can cause serious injury.