Installation / Initial Set-Up

 

The generator cannot power your entire home -- you must work with the

 

installing electrician to determine which devices/appliances you wish to

 

power during an outage. The electrician can help you determine which

 

circuits and devices can be powered simultaneously without overloading the

 

generator.

 

 

 

 

 

(See the previous section of this manual entitled “Power Load Planning &

 

Management” for more information on load application and selection.)

Using as a

When using the generator as a portable power source, you can plug

Portable Power

electric devices and appliances directly into the generator’s electrical

Source

outlets.

 

 

 

 

 

There are four different kinds of electrical outlets on the generator:

 

1. One 120/240 Volt, 50 Amp straight-blade receptacle (NEMA 14-50R

 

receptacle compatible with NEMA 14-50P mating plug)

 

2. One 120/240 Volt, 30 Amp locking receptacle (NEMA L14-30R

 

locking receptacle compatible with L14-30P mating plug)

 

3. One 120 Volt, 30 Amp locking receptacle (NEMA L5-30R receptacle

 

compatible with NEMA L5-30P mating plug)

 

 

4. Two 120 Volt, 20 Amp duplex straight-blade receptacles (NEMA 5-

 

20R duplex receptacles compatible with NEMA 5-20P or 5-15P

 

mating plugs).

 

 

 

 

 

 

 

 

CIRCUIT BREAKERS

 

 

 

120V

20A

120/240V-30A

120/240V-50A

 

13000 PPG 120V

20A

 

 

 

PRO SERIES

 

 

 

 

 

GENERATOR 120V

30A

 

 

 

120V-20A

120V-30A

120/240V-30A

120/240V-50A

 

(2) NEMA

 

 

 

 

 

5-20R

 

 

 

 

 

Duplex

 

 

 

 

Please read your owner's manual before operating, if you do not have a manual or have questions, call customer service at 1-800-270-0810

NEMA NEMA NEMA

L5-30R L14-30R 14-50R

(See more technical detail about these receptacles and their associated circuit breakers in the “Machine Component Identification” section of this manual.)

Make sure you plug each electrical device/appliance into the correct generator outlet based on the device’s plug configuration and voltage/amperage rating. Never exceed the amperage rating of an outlet.