North Star M165939J owner manual Troubleshooting

Models: M165939J

1 50
Download 50 pages 56.73 Kb
Page 39
Image 39

Troubleshooting

TROUBLESHOOTING

Problem

Possible Causes

Possible Remedies

Engine will not start.

Voltage too low.

Circuit breaker trips.

Voltage too high.

Generator overheating.

No output voltage.

Engine lacks power or sputters.

Engine shuts down during operation.

a)Low oil level.

b)Fouled spark plug.

c)Out of fuel.

d)Stop switch in OFF position.

e)Battery disconnected or dead.

f)Fuel selector switch is set to the incorrect fuel.

a)Engine speed too slow.

b)Generator is overloaded.

a)Defective load connected to generator.

b)Defective receptacle.

c)Generator overloaded.

a)Engine speed too high.

a)Generator is overloaded.

b)Insufficient ventilation.

a)Defective load connected to generator.

b)Broken or loose wire.

c)Defective receptacle.

d)Defective stator.

e)Defective rotor.

f)Defective capacitor.

a)Generator is overloaded.

b)Dirty air filter.

c)LP/NG hose is connected to the wrong Carburetor inlet.

d)Fouled spark plug.

a)Out of fuel.

b)Low oil level.

a)Fill crankcase to proper oil level.

b)Clean or replace spark plug.

c)Fill fuel tank.

d)Place switch in ON position.

e)Charge or replace battery.

f)Place switch in desired location (Gasoline or LP/NG).

a)Bring generator to a qualified technician for adjustment.

b)Reduce the load. (See Power Load Planning & Mgt. section of this manual.)

a)Disconnect load.

b)Replace receptacle.

c)Reduce the load. (See Power Load Planning & Mgt. section of this manual.)

a)Bring generator to a qualified technician for adjustment.

a)Reduce the load. (See Power Load Planning & Mgt. section of this manual.)

b)Make sure there is at least 3 feet of clearance on all sides of generator.

a)Disconnect load.

b)Bring generator to a qualified technician for repair.

c)Replace receptacle.

d)Bring generator to a qualified technician for repair.

e)Bring generator to a qualified technician for repair.

f)Bring generator to a qualified technician for repair.

a)Reduce the load. (See Power Load Planning & Mgt. section of this manual.)

b)Clean or replace air filter.

c)For LP, the hose should be on the left inlet, For NG, the hose should be on the right inlet.

d)Clean or replace spark plug.

a)Fill fuel tank.

b)Fill crankcase to proper oil level.