Machine Component Identification - Item #165939J
REFERENCE GUIDE
| Reference 1 – Air Cleaner | Refer to your Honda engine manual for air cleaner care. | |
| Reference 2 – Gas Cap with Gauge | The gas cap is extra large, creating a large hole for refueling |
|
|
| and a comfortable grip. You can always monitor the fuel level |
|
|
| without removing the cap by using the fuel level indicator built |
|
|
| into the gas cap. |
|
| Reference 3 – 10.0 Gallon Gas Tank | Large tank allows for extended run capabilities. Always allow |
|
|
| room for gasoline expansion by not filling the gas tank | |
|
| completely full. | |
| Reference 4 – Battery Box | The battery box provides protection for the battery and will accept |
|
|
| the standard lawn tractor size battery (Group |
|
|
| requires a 12 volts battery. See battery section for sizing. |
|
| Reference 5 - | WARNING Hookup must comply with the Federal and Local |
|
| Inlet | jurisdiction of Liquid Petroleum (LP) and Natural Gas (NG). | |
|
| ALWAYS have a qualified technician complete the LP/NG | |
|
| hookup. Improper installation can cause injury or death. LP/NG | |
|
| are lethal and explosive gases. If you smell gas, exit area | |
|
| immediately, if possible shut off the LP/NG supply. Before you | |
|
| start engine, smell next to floor for gas, if you do smell gas: | |
|
| • DO NOT start engine. | |
|
| • DO NOT light a match. | |
|
| • DO NOT flip on an electrical switch. | |
|
| • Exit area immediately and call gas supplier or fire | |
|
| department. | |
|
| Minimum flow range required: NG - 3.25 CFM; | |
|
| LPG - 9.33 LB/hr., or 2.2 GAL/hr. | |
|
| Pressure Range: | |
|
| NEVER over pressurize. | |
| Reference 6 - 120/240V, 50A, Circuit | This portable generator has one 120/240 volt, 50 Amp thermal |
|
| Breaker | magnetic 2 pole circuit breaker. This circuit breaker is the main |
|
|
| line circuit breaker and will sever power to the control panel |
|
|
| receptacles when in the off or tripped position. To reset this circuit |
|
|
| breaker, move the circuit breaker handle to the OFF position. |
|
|
| Then move the breaker handle to the ON position. If the circuit |
|
|
| breaker continues to trip, reduce load to the generator. If |
|
|
| nuisance tripping continues one or more electrical loads may be |
|
|
| defective and must be repaired by a qualified electrician. |
|
| Reference 7 - 120/240V, 50A | The generator control panel has one 120/240 volt, 50 amp NEMA |
|
| Receptacle | ||
|
| The mating plug for this receptacle is a NEMA | |
|
| receptacle is useful when installing a transfer switch. | |
| Reference 8 - 120/240V, 30A | The generator control panel has one 120/240 volt, 30 amp |
|
| Receptacle | NEMA |
|
|
| protected by Reference 9. The mating plug for this receptacle is |
|
|
| a NEMA |
|
| Reference 9 - 120/240V, 30A, Circuit | This generator has one 120/240 volt, 30 Amp thermal magnetic |
|
| Breaker | 2 pole circuit breaker. To reset this circuit breaker, move the | |
|
| circuit breaker handle to the OFF position. Then move the | |
|
| breaker handle to the ON position. | |
| Reference 10 - 120V, 30A Receptacle | The control panel has one 120 volt, 30 amp NEMA |
|
|
| receptacle. This receptacle is protected by Reference 11. The |
|
|
| mating plug for this receptacle is a NEMA |
|
| Reference 11 - 120V, 30A Circuit | The generator control panel has a |
|
| Breaker | circuit breaker. To reset the circuit breaker, wait 15 seconds | |
|
| and press the extended button back into the circuit breaker | |
|
| housing. | |
| Reference 12 - 120V, 20A Circuit | The generator control panel has two 120 volt, 20 amp thermal |
|
| Breaker | circuit breakers. To reset the circuit breaker, wait 15 seconds |
|