Northern Industrial Tools 1/2 HP SUMP PUMP owner manual Problem, Possible Cause, Remedy

Models: 1/2 HP SUMP PUMP

1 8
Download 8 pages 51.55 Kb
Page 7
Image 7
PROBLEM

6

 

PROBLEM

 

POSSIBLE CAUSE

 

REMEDY

 

 

 

 

 

 

1. THE ELECTROPUMP DOES NOT PUMP

 

1.

No electricity.

 

 

 

 

 

 

WATER, THE MOTOR DOES NOT RUN.

 

2.

Plug inserted incorrectly.

 

Verify that voltage is present and

 

 

 

 

 

 

 

 

 

that the plug is correctly inserted.

 

 

 

 

 

3.

Enabled safety switch.

 

Reset the safety switch. If the safety

 

 

 

 

 

 

 

 

 

switch is once more enabled, Contact a

 

 

 

 

 

 

 

 

speciallzed electrician.

 

 

 

 

 

4.

Blocked safety switch.

 

Remove possible obstructions from the

 

 

 

 

 

 

 

 

impeller.

 

 

 

 

 

5.

Damaged motor or condenser.

 

Contact the Customer Assistance Service.

 

 

2. THE PUMP DOES NOT SUPPLY WATER

 

1.

Obstructed suction grid.

 

Clean the grid.

 

 

 

 

BUT THE MOTOR IS RUNNING.

 

2.

Blocked check valve.

 

Clean or replace the value.

 

 

 

 

 

 

3.

Air in impeller body (air Bubbles.)

 

Perform several start-ups in order to

 

 

 

3.

THE PUMP SUPPLIES A LIMITED

 

 

 

 

remove all the air.

 

 

 

1.

Partially obstructed suction gird.

 

Clean the grid.

 

 

 

 

AMOUNT OF WATER.

 

2.

Obstructed pipe.

 

Remove the obstructions.

 

 

 

 

 

 

3.

Wom impeller.

 

Contact the Customer Assistance Service.

 

 

 

4.

INTERMITTENT OPERATION

 

1.

Solid particles prevent the free

 

Renmove the foreign particles.

 

 

 

 

 

 

 

rotation of the impeller.

 

 

 

 

 

 

 

 

2.

The temperature of the fluid is

 

 

 

 

 

 

 

 

 

too high.

 

Supply the pump in accordance with

 

 

 

 

 

 

3.

Vollage out off range.

 

 

 

 

 

 

 

 

 

 

nameplate data.

 

 

 

 

 

4.

The fluid is too dense.

 

Dilute the pumped fluid.

 

 

 

 

 

5.

Faulty motor.

 

Contact the Customer Assistance Service.

 

 

Page 7
Image 7
Northern Industrial Tools 1/2 HP SUMP PUMP owner manual Problem, Possible Cause, Remedy