LOGGING DATA
An extensive set of logs has been created to capture the data your
To log data, use the LOG command. For example, to log the pseudorange position to COM 1 every 30 seconds, enter the following:
log com1 psrposb ontime 30
When requesting logs, you can request the output data in three formats:
•ASCII
•Abbreviated ASCII
•Binary
Abbreviated ASCII is the best format to use when you want to work with the receiver directly and review individual log contents visually.
Refer to the
If you prefer, Connect provides a graphical interface for configuring data logging. Select Logging Control Window from the Tools menu. In the Logging Control window, you can select which logs to capture and choose the ports to which you want the data sent. You can also specify a file in which to save the data.
When logging data through Connect, close all unused windows to maximize COM port throughput and receiver CPU performance.
QUESTIONS OR COMMENTS
If you have any questions or comments regarding your
Email: support@novatel.com
Web: www.novatel.com
Phone:
Fax:
NovAtel, GL1DE and OEMV are registered trademarks of NovAtel Inc.