BEFORE SWITCHING OFF THE POWER

CDN 36

BEFORE SWITCHING OFF THE POWER

When you have finished using the CD player, be sure that the disc tray is closed with the “OPEN/CLOSE” button before switching off the power.

DO NOT switch off the power when

Switch off the power after the

the disc holder is open.

disc holder has been closed

 

with the “OPEN/CLOSE” button

TROUBLESHOOTING

Symptom

Possible Cause

Corrective Action

 

 

 

The power fails to switch on when

Poor power plug connection at the

Insert the power plug firmly into

the POWER switch is set to on

AC outlet or IEC Power cord loose

the AC outlet and make sure

 

from rear of unit

connection is good in unit rear

Disc play does not start

The disc is loaded upside down

Reload the disc with the label side

 

The disc is too dirty

up

 

 

 

 

Clean the disc

 

 

 

No sound

Improper output cable

Connect the output cables

 

connections

correctly

 

Improper amplifier operation

Check amplifier setup

Sound skips

The CD player is subject to

Change the installation location

 

vibrations or physical shock

 

 

The disc is too dirty

Clean the disc

Hum

Loose cable connections

Firmly connect all audio plugs

 

 

 

 