PLANNING - (continued) |
| PLAN THE DUCTWORK |
Note: The high level of air flow of this appliance may affect the gas flame on some types of gas cooktops. This is NORMAL and will cause no harm, but can be corrected by lowering the speed of the blower.
SPECIFICATIONS
VOLTS | AMPS | CFM | DUCT |
120 | 4.0 | 500 |
TAKE MEASUREMENTS
1.Refer to the cooktop installation instructions for dimensions of cooktop, countertop
2.Cooktop depth can vary greatly from one to another. This may cause the fit of these two appliances to be rather tight.
Pay special attention to the areas of potential interference highlighted above. A countertop with (A) a raised lip and/or (B) a backsplash may not allow enough flat countertop for a proper installation. Note that 2" of flat countertop is required behind cooktop and that
RIGHT
DISCHARGE
LEFT
DISCHARGE
DOWN DISCHARGE (as shipped)
1.This downdraft blower system is designed for use with
2.For best performance: Choose the ducting option which allows the shortest length of ductwork and a minimum number of elbows and transitions. Check location of floor joists, wall studs, electrical wiring or plumbing for possible interference. NOTE: The unit is shipped with the
6" ROUND | |
ELBOW | TO 6" RD. |
| TRANSITION |
EQUALS 6 FT. OF | EQUALS 2 |
FT. OF | |
STRAIGHT DUCT | STRAIGHT DUCT |
90O ELBOW
EQUALS 8
FT. OF
STRAIGHT DUCT
3.The system will operate most efficiently when the ductwork does not exceed 40 feet of equivalent duct. The chart, above, shows equivalent feet of elbows and transitions. The number of feet of straight duct plus the equivalent feet of transitions and/or elbows to be used should equal 40 feet or less.
NOTE: The equivalent feet of various roof and wall caps has been taken into consideration. Do not include them in this calculation.
PLAN THE WIRING
1.The downdraft blower system draws 4 AMPS and requires a 120 VAC, 60 Hz circuit.
2.The unit has a 2 ft. long power cord with a
2