NuTone important safety instructions Ductless Fan, MODEL 682NT, Important Safety Instructions

Models: 682NT

1 8
Download 8 pages 13.64 Kb
Page 1
Image 1
Ductless Fan

INSTALLATION INSTRUCTIONS READ & SAVE THESE INSTRUCTIONS!

Ductless Fan

MODEL: 682NT

IMPORTANT SAFETY INSTRUCTIONS

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN- JURY TO PERSONS, OBSERVE THE FOLLOWING:

1.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.

2.Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a promi- nent warning device, such as a tag, to the service panel.

3.Installation work and electrical wiring must be done by a quali- fied person(s) in accordance with all applicable codes and stan- dards, including fire-rated construction codes and standards.

4.Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authori- ties.

5.When cutting or drilling into wall or ceiling, do not d a m a g e electrical wiring and other hidden utilities.

6.Ducted fans must always be vented to the outdoors.

7.If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

8.Never place a switch where it can be reached from a tub or shower.

9.This unit must be grounded.

CAUTION

1.For general ventilating use only. Do not use to exhaust haz- ardous or explosive materials and vapors.

2.To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc., off power unit.

3.Please read specification label on product for further information and requirements.

PLAN THE INSTALLATION

Refer to FIGURE 1

Determine where fan will be located and plan to supply fan with proper line voltage and appropriate power cable.

Follow these basic steps when installing this fan:

Attach mounting bracket to joist or stud.

Snap fan housing onto bracket.

Wire fan.

Attach grille (after ceiling or wall is finished).

7-1/8”

7-1/8”

6-1/4”

8-1/2”

8-1/2”1”

ROUGH-IN OPENING SIZE IS 7-1/4” x 7-1/4”

FIGURE 1