INSTALLATION INSTRUCTIONS
READ & SAVE THESE INSTRUCTIONS!
Room-to-Room Fan
MODEL: 8145
IMPORTANT SAFETY INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE. |
| |
ELECTRIC SHOCK, OR INJURY TO PERSONS, | INNER | |
OBSERVE THE FOLLOWING: | SLEEVE | |
A. Use this unit only in the manner intended by the | EXTENSION | |
manufacturer. If you have questions, contact the | ||
BRACKET | ||
manufacturer. | ||
| ||
B. Before servicing or cleaning unit, switch power off at |
| |
service panel and lock service panel to prevent |
| |
power from being switched on accidentally. |
| |
When the service disconnecting means cannot be |
| |
locked, securely fasten a prominent warning device, | FAN AND | |
such as a tag, to the service panel. | MOTOR | |
CAUTION: | ASSEMBLY | |
For general ventilating use only. Do not use to |
| |
exhaust hazardous or explosive materials and vapors. |
|
INSTALLATION INSTRUCTIONS |
|
| KNOCKOUTS |
| ||
WARNING: TO REDUCE THE RISK OF FIRE, |
|
| AIR FLOW | |||
ELECTRIC SHOCK, OR INJURY TO PERSONS, |
|
| ||||
OBSERVE THE FOLLOWING: | OUTER |
| ||||
A. Installation work and electrical wiring must be done |
| |||||
by qualified person(s) in accordance with all | SLEEVE |
| ||||
| ON/OFF SWITCH | FIGURE 1 | ||||
applicable codes and standards, including |
|
|
| |||
|
|
|
| |||
construction. |
|
|
|
|
| |
B. Sufficient air is needed for proper combustion and |
| NEW CONSTRUCTION |
| |||
exhausting of gases through the flue (chimney) of fuel |
|
| ||||
burning equipment to prevent back drafting. Follow the |
| ADJUSTING AND MOUNTING FAN SLEEVE | ||||
heating equipment manufacturer's guideline and safety |
| |||||
| 1. Remove four (4) screws to separate outer sleeve | |||||
standards such as those published by the National Fire |
| |||||
| from inner sleeve. |
| ||||
Protection Association (NFPA), and the American Society |
|
| ||||
| 2. The outer sleeve is the discharge side of the fan; make | |||||
for Heating, Refrigeration and Air Conditioning Engineers |
| |||||
| sure the on/off switch is in the room into which air will | |||||
(ASHRAE), and the local code authorities. |
| |||||
| be blown. |
| ||||
C. When cutting or drilling into wall or ceiling, do not damage |
|
| ||||
electrical wiring and other hidden utilities. |
| 3. Insert extension bracket in top of outer sleeve. | ||||
D. Ducted fans must always be vented to the outdoors. |
| 4. Refer to Figure 1. Loosen two screws and remove | ||||
E. If this unit is to be installed over a tub or shower, it must |
| fan and motor assembly from adjustable inner sleeve. | ||||
be marked as appropriate for the application. |
| 5. Adjust to wall thickness by removing knockouts in bottom | ||||
F. NEVER place a switch where it can be reached from |
| of adjustable sleeve. Refer to chart. | ||||
a tub or shower. |
|
|
|
| ||
| Wall Thickness |
| Remove Knockouts | |||
For use on inside walls which are 31⁄2" to 6" thick. |
|
| ||||
|
|
|
| |||
|
|
|
| |||
The telescoping sleeve is adjusted to wall thickness |
| 6" |
| 0 | ||
by removing knockouts. |
| 5" – 51⁄2" |
| 1 | ||
• WARNING: To reduce risk of fire or electrical shock, |
| 41⁄2" – 5" |
| 2 | ||
this fan should not be used with an additional speed |
| 4" – 41⁄2" |
| 3 | ||
control. |
| 31⁄2" – 4" |
| 4 | ||
• WARNING: To reduce the risk of shock, disconnect |
|
|
|
| ||
| 6. When adjusting sleeve, make sure both flanges will | |||||
power before servicing. |
| |||||
• Do not mount over tub or in shower stall enclosure. |
| be flush with finished walls. |
| |||
To move heated air from one room to another, NuTone |
| 7. When adjustment is complete, screw sleeves together | ||||
recommends installing the |
| with four (4) screws. |
| |||
| 8. Center and mount completed sleeve assembly to a wall | |||||
inches of the ceiling. Installing the fan at this height will |
| |||||
provided more efficient movement of heated air from room |
| stud. Nail or screw sleeve to wall stud through holes in | ||||
to room. |
| the side of the sleeve. |
| |||
If the fan is intended to move cooled air from room |
| 9. Refer to Figure 2. Extend bracket to opposite wall stud | ||||
to room, install the fan as close as possible to the floor. |
| and secure it with nails or screws. |