INSTALLATION INSTRUCTIONS READ & SAVE THESE INSTRUCTIONS!
Bathroom Ventilator
MODELS: 8832WH, 8832SA & 8833
•Do not mount over tub or in shower stall enclosure.
•Not for use in kitchens.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE. ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
B. Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
CAUTION:
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
INSTALLATION INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including
B. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA),and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
C. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
D. Ducted fans must always be vented to the outdoors. E. If this unit is to be installed over a tub or shower, it must
be marked as appropriate for the application.
F. NEVER place a switch where it can be reached from a tub or shower.
G. Do not use this fan with any
FOR BEST RESULTS
When installing the ventilator in a new construction site, install the housing during the
To install the ventilator in an existing house requires accessible area above the proposed installation location (attic or crawl space). The housing must be installed to a finished ceiling from above.
LOCATION
The ventilator is intended for installation in bathroom or laundry.
CAUTION: Do not install the unit over a tub or in a shower stall enclosure.
INSTALLATION IN A NEW
CONSTRUCTION SITE
1.Remove the blower unit from the housing by unplugging it then loosening the three mounting screws and rotating the unit to free it from the screws.
|
| ROOF |
|
| CAP |
ADJUSTABLE |
|
|
ELBOW |
|
|
| 3" | WALL |
| ROUND | |
| CAP | |
| DUCT | |
|
| |
IN CEILING |
|
|
TRANSITION |
| |
FURNISHED |
| |
WITH WALL CAP | FIGURE 1 | |
|
| |
|
|
|
|
|
|
| ROOF |
|
| CAP |
|
ADJUSTABLE | WALL | |
CAP |
| |
ELBOW |
| |
|
| |
3" | TRANSITION |
|
ROUND | FURNISHED |
|
DUCT | WITH WALL CAP | |
IN WALL |
| FIGURE 2 |
|
|
|
GREEN
GROUND
SCREW
JUNCTION
BOX
STANDARD | SWITCH | |
WALL | ||
BOX | ||
SWITCH | ||
|
120vAC, 60Hz
HOUSE POWEREARTH GROUND
FIGURE 3
2.Loosely attach housing to ceiling joists through keyhole slots in mounting brackets. Keyhole slots in brackets are provided to allow for adjustment to various ceiling thicknesses. Adjust housing so bottom is flush to proposed finished plaster line, then securely fasten housing to joists.