INSTALLATION INSTRUCTIONS
READ & SAVE THESE INSTRUCTIONS!

Wall Heater

MODELS: 9192NT, 9194NT, 9198NT

IMPORTANT SAFETY INSTRUCTIONS

 

PLAN THE INSTALLATION

WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOW- ING:

1.All electrical work must be done in accordance with local or national electrical code as applicable. For safety, this product must be grounded. If you are unfamiliar with methods of in- stalling electrical wiring, secure the services of a qualified elec- trician.

2.When wiring, servicing or cleaning this unit, turn off power and lock out service panel. Failure to do so could allow others or thermostat to turn on power unexpectedly which may cause fatal electrical shock.

3.To avoid electrical shock:

Do not install unit in a tub or shower enclosure or any loca- tion where it may come in contact with water.

Never place a switch where it can be reached from a tub or shower.

4.Do not install this unit in an area where chemicals and other flammables are stored or used. Explosion and fire may result.

CAUTION

1.This product may ONLY be installed in a wall. Do not mount in any other position.

2.Install heater at least 12" from floor or any adjacent vertical surface.

3.Do not locate heater behind a door, furniture, drapes, etc., where the air flow to the unit would be restricted.

4.Provide heater with an appropriately-rated electrical circuit to prevent tripped breakers or blown fuses.

5.Do not connect heater to dimmer switch or speed control.

6.To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc., off power unit.

7.Please read specification label on product for further informa- tion and requirement.

1

This heater is intended to be used to supply supplemental heat from a wall location in new or existing construction.

Choose a location where edge of heater will be at least 12" from the floor or any adjacent vertical surface.

The heater can be operated using its built-in thermostat or a remote thermostat (Choose either the Model 86W Line-Voltage thermostat or use the Model 82 Transfomer/Relay with an appropriate low-voltage thermostat.). The Model 85NT Kit is available for surface -mount applications. Purchase these accessories separately.

Plan to supply the heater with proper line voltage and appropriate power cable.

NOTE: Power can be tapped from a nearby circuit depending on the heater wattage required and the amperage rating of the circuit.

Heater can be converted to half-wattage to avoid overloading such circuits.

MODEL

VOLTS

AMPS

WATTS

BTU/HR

9192NT

240

8.33/4.17

2000/1000

6827/3413

9194NT

240

12.50/6.25

3000/1500

10240/5120

9198NT

240

16.67/8.33

4000/2000

13653/6827

Bold ratings are factory wired.

See “OPTIONAL WIRING CONVERSIONS” section for wattage conversion instructions.

Refer to FIGURE 1

Follow these basic steps when installing this heater:

1)Nail housing to studs.

2)Connect power cable.

3)Fasten heater assembly and grille to housing.

DRYWALL

 

THERMAL

HEATER HOUSING

OVERLOAD

 

GRILLE

 

BUILT-IN

THERMOSTAT

POWER CABLE