INSTALL THE HEATER
Refer to FIGURE 2
1.Remove heater assembly from housing. Take out the four (4) screws shown and set heater assembly aside.
Refer to FIGURE 3
2. Attach housing to wall studs.
NOTE: Locate housing at least 12" from floor on any adjacent walls.
Use the measuring guides on the sides of housing to position housing so that it will be flush with finished wall. Nail the housing to studs through the hole and slot on both sides of housing.
NOTE: In
WIRE THE HEATER
Refer to FIGURE 4
1.Connect power cable to housing. Attach electrical power cable to housing using appropriate connector. Allow 6" of wire inside housing. Secure ground wire to housing with grounding clip, as shown.
Refer to FIGURE 5 and FIGURE 6
2.Wire the heater assembly. Connect wires from heater assem- bly to power cable wires. Follow wiring diagram.
If heater is wired direct, use the
OPTIONAL WIRING CONVERSIONS
When using a separate wall control, simply turn the heater's builtin thermostat to its highest setting. There is no need to disconnect the
a)Turn
b)Remove knob.
c)Fasten security cover to grille.
Refer to FIGURE 7
If
Cut blue wire. Strip ½” of insulation from each end. Connect wires from wall control to each stripped wire.
If
Refer to FIGURE 8
The heater will produce less heat and use less electricity if converted to
2
THERMAL OVERLOAD “RESET”
BUTTON
HEATER
ASSEMBLY
MOUNTING
SCREWS
THERMOSTAT
FIGURE 2
NAIL HERE –
BOTH SIDES
MEASURING
GUIDES
FIGURE 3
GROUNDING CLIP DETAIL
FIGURE 4
FIGURE 5