INSTALL THE HEATER

Refer to FIGURE 2

1.Remove heater assembly from housing. Take out the four (4) screws shown and set heater assembly aside.

Refer to FIGURE 3

2. Attach housing to wall studs.

NOTE: Locate housing at least 12" from floor on any adjacent walls.

Use the measuring guides on the sides of housing to position housing so that it will be flush with finished wall. Nail the housing to studs through the hole and slot on both sides of housing.

NOTE: In 24"-on-center stud construction, framing in between studs is necessary.

WIRE THE HEATER

Refer to FIGURE 4

1.Connect power cable to housing. Attach electrical power cable to housing using appropriate connector. Allow 6" of wire inside housing. Secure ground wire to housing with grounding clip, as shown.

Refer to FIGURE 5 and FIGURE 6

2.Wire the heater assembly. Connect wires from heater assem- bly to power cable wires. Follow wiring diagram.

If heater is wired direct, use the built-in thermostat for tempera- ture control.

OPTIONAL WIRING CONVERSIONS

When using a separate wall control, simply turn the heater's builtin thermostat to its highest setting. There is no need to disconnect the built-in thermostat:

a)Turn built-in thermostat to highest setting.

b)Remove knob.

c)Fasten security cover to grille.

LINE-VOLTAGE THERMOSTAT

Refer to FIGURE 7

If wall-mounted control is desired, use the Model 86W Line-Voltage Thermostat. Purchase thermostat separately.

Cut blue wire. Strip ½” of insulation from each end. Connect wires from wall control to each stripped wire.

LOW-VOLTAGE THERMOSTAT

If wall-mounted control is desired, use a Model 82 Transfomer/ Relay with an appropriate low-voltage thermostat (purchase sepa- rately). Follow the mounting and wiring instructions packed with the controls.

HALF-WATTAGE CONVERSION

Refer to FIGURE 8

The heater will produce less heat and use less electricity if converted to half-wattage. Remove the black jumper wire from the heating element and discard wire.

2

THERMAL OVERLOAD “RESET”

BUTTON

HEATER

ASSEMBLY

MOUNTING

SCREWS

THERMOSTAT

FIGURE 2

NAIL HERE –

BOTH SIDES

MEASURING

GUIDES

FIGURE 3

GROUNDING CLIP DETAIL

FIGURE 4

FIGURE 5