TYPICAL SYSTEM LAYOUT CONTINUED

MODEL 301T

TRANSFORMER

120vAC, 60Hz

HOUSE POWER. OBSERVE LOCAL CODE.

NUTONE IW-6 MAX. 4000 FT.

PER SYSTEM. MAX. 500 FT.

ANY ONE RUN

18/2

(NUTONE S-143)

IMA-516

CENTRAL AMPLIFIER

ORN / WHT BLK

BLK

ORN

BLK / WHT

PAIR

 

 

NOT

 

 

USED

14 GA

AC

 

CHIME

FIELD

 

GROUNDING

 

WIRE

CHIME

AC

 

18 GA

N482BX

 

BLK/W

 

ORN/W

 

RED

IW-2 (100 FT. MAX.)

 

NUTONE

OPTIONAL

 

DOOR

 

RELEASE

DOOR SPEAKER GA18

BLK

ORN

RED/W

NUTONE IW-2 (100 FT. MAX.)

TO APT.

NO. 3

N482BX

TO APT.

NO. 3

IW-6

IW-6

TO APT.

NO. 1

OPTIONAL

DOOR

RELEASE

18 GA

RED RED / WHT

18 GA 2000 FT. MAX. TO LAST DOOR RELEASE.

2500 FT. MAX. TO LAST SPEAKER BUZZER

PUSH BUTTON

DOOR SPEAKER

PUSH

BUTTON

TO APT

NO. 3

APARTMENT NO. 1

APARTMENT NO. 2

TOWNHOUSE APARTMENTS

A typical system includes individual door speakers and apartment speakers with built-in door buzzer. As an option, an electric door release may be used.