NuTone Nm100WH NM100 NuTone Wire function Connection IWA3 Cable, Replacing the Room Stations

Models: Nm100WH

1 32
Download 32 pages 21.6 Kb
Page 4
Image 4

model NM100WH

For the NWH300C Master Station and CD combination rough-in, have a qualified electrician loop a power wire from the NA200TA transformer enclosure to the NA300TA transformer enclosure following the same procedure described previously and shown in the next figure.

 

 

Page 

Three-wire Installations

 

 

 

 

NM100

NuTone

wire function

connection

IWA3 Cable

 

 

 

 

Black

Blue Stripe or

Intercom Mic

 

Outside Copper Wire

Audio Input & Control

 

 

Red

Center Wire

Ground

 

 

 

Green

Red Stripe or Outside

Speaker

 

Silver Wire

Output/Monitor

 

 

 

 

Mic Input

 

 

 

Replacing the Room Stations

The remote and door stations use the existing wire and station rough-in mounting frames or boxes. To replace the station, first remove the old station. Leave the existing remote or door station rough-ins in place.

After removing the remote station verify the integrity of the wire run. Then install the mounting plate from the NF300RWH frame. Align the plate on the wall either vertically or horizontally so that the screw holes line up with those on the rough-in or box. Use a level to make sure the plate is level. There are several screw hole locations on the mounting plate so it can attach to many rough-in designs. Mount the plate to the wall using the screws provided.

Next connect the wires to the retrofit remote station. Match the wire colors to the corresponding screw locations on the NRS103WH or NRS104WH remote stations. Please make sure to use only NRS103WH remote stations in a 3-wire installation and NRS104WH remote stations in a 4-wire installation. All 6-wire installations use the NRS200WH remote stations. Please refer to appendix A for a diagram of which NuTone and M&S systems map to the 3, 4 or 6- wire (requires NM200 master) configurations. Refer to the following two charts for the NM100 wiring diagram:

Four-wire Installations

NM100

NuTone 4

M&S 4

Wire

CONNECTION

Conductor

Conductor

Function

 

with Gray

Cable

 

 

Jacket

with Gray

 

 

 

Jacket

 

White

Blue Stripe

Silver Outside

Intercom Mic

 

Wire

Gray Wire

Audio Input

Black

Gray/Copper

Next Copper

Intercom

 

Wire

Outside Gray

Control

 

 

Wire

 

Red

Gray/Silver

Next Copper

Ground

 

Wire

Outside Gray

 

 

 

Wire

 

Green

Red Stripe

Outside

Speaker

 

Wire

Copper

Output/Monitor

 

 

Outside Red

Mic Input

 

 

Stripe Wire

 

NM100

M&S MS4XSC

NUTONE

WIRE

CONNECTION

CABLE

NW4S CABLE

FUNCTION

 

 

 

 

White

White

Red

Intercom Mic

 

 

 

Audio Input

Black

Black

Black

Intercom

 

 

 

Control

Red

Red

Orange

Ground

Green

Green

Yellow

Speaker

 

 

 

Output/Monitor

 

 

 

Mic Input

Connect the remote station to the existing wiring using the diagrams above. Place the remote station through the NF300RWH plastic mounting frame. Position the frame either vertically or horizontally depending on the remote station replaced. Place the remote station into the rough-in ring and align the frame with the remote station.

Page 4
Image 4
NuTone Nm100WH installation instructions NM100 NuTone Wire function Connection IWA3 Cable, Replacing the Room Stations