8. INSTALL THE ADAPTER (INTERIOR BLOWER)

8. INSTALL THE ADAPTER (INTERIOR BLOWER)

Using two (2) standard 1/2’’ screws, secure the adapter to the top (or back) of the hood. Seal the adapter to the hood using duct tape.

HD0005

HD0006

9. INSTALL THE HOOD (ALL BLOWERS)

INTERIOR BLOWER: Run power cable to installation location. Place the hood to its location. Mark the position of the screws (smaller part of the key holes) with a pen. Remove the hood and install the (8) 1/2” double thread screws leaving a 1/8” gap (4 screws for 30” hood). Remove wiring cover, place the wire clamp, insert the cable in the hood and tighten the wire clamp to secure the cable. Place the hood under the cabinet and slide it in position. Make sure the adapter/damper assembly enters the ducting. Secure the hood by tightening the screws completely.

HD0043

EXTERIOR OR IN-LINE BLOWER: Run power cable to installation location. Place the hood to its location. Mark the position of the screws (smaller part of the key holes) with a pen. Remove the hood and install the (8) 1/2” double thread screws leaving a 1/8” gap (4 screws for 30” hood). Remove wiring cover on top of the hood and connect wiring (see instructions included with exterior or in-line blower). Place the hood under the cabinet and slide it in position. Secure the hood by tightening the screws completely.