model nsp130
cleaning & Maintenance
For performance, appearance, and health reasons, clean filter, fan and
The motor is permanently lubricated and never needs oiling. If the motor bearings make excessive or unusual noise, replace the motor with the exact service motor. The impeller should also be replaced.
Page
prepare hood location
ROOF CAP
3¼" X 10" (For vertical discharge)
Use 120 V, 50 W, shielded halogen bulbs - MR16 or PAR16 with GU10 base. Purchase bulbs separately.
The grease filters, bottom panel, and blower wheel should be cleaned frequently. Use a warm detergent solution. The grease filters and blower wheel are dishwasher safe.
Note: Some minerals, when in contact with dishwasher soap additives, may cause filters to discolor. This discol- oration is not covered by the warranty.
SOFFIT |
CABINET |
HOOD |
18" - 24" ABOVE |
COOKING SURFACE |
HOUSE WIRING (Top or Back of hood)
WALL CAP
3¼" X 10" DUCT
(For horizontal discharge)
operation
Always turn the hood ON before cooking in order to establish an air flow in the kitchen. After turning off the range, let the hood run for a few minutes to clear the air.
HEAT SENTRY™
The hood is equipped with a Heat Sentry™ thermostat. This safety device will turn on or speed up the blower if it senses excess heat above the cooking surface.
If the blower is not on, or if it is running at low speed, the Heat Senttry™ will override the normal blower control and trun the blower on the high speed. When the temperature level drops to normal levels, the blower will return to its original setting.
Operate the hood as follows:
Blower Switch
This
Set switch to (1) position to turn blower ON to low speed. Set switch to (2) position to turn blower ON to high speed. Set switch to (0) position to turn blower OFF.
light switch
This
Set switch to (1) position to turn lights ON to low intensity. Set switch to (2) position to turn lights ON to high intensity. Set switch to (0) position to turn lights OFF.
1 Determine whether hood will discharge vertically or hori- zontally. For vertical or horizontal discharge, run ductwork between the hood location and a roof cap or wall cap. For best results, use a minimum number of transitions and
elbows.