CAUTIONS

WARNING: To reduce the risk of personal injury, do not bend the blade brackets when installing the brackets, balancing the blades, or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

WARNING: To reduce the risk of fire, electric shock, or personal injury, mount to outlet box marked “Acceptable for Fan Support” and use mounting hardware provided with the box.

WARNING: To reduce the risk of fire or electrical shock, do not use this fan with any solid-state speed control device.

This product must be mounted and wired in compliance with all local and national electrical codes.

Before wiring the ceiling fan, turn off electric power at the circuit breaker or fuse box and leave off until installation is complete.

Mount outlet box so that it will support at least 35 pounds. Note: the weight of the fan is as follows:

PFC-48 14 lbs.

PFC-56 20 lbs.

LOCATION

1.When fan is installed, you must allow a minimum of 10 feet between floor and bottom of fan blades.

2.For this model, the center of the fan must be located at least 32" from any vertical surface – wall, doors, partitions, etc. This allows minimum clearance for fan blades.

3.Do not mount fan below, next to or between air ducts, beams or any other obstructions which may interfere with the natural air flow pattern created by the fan.

4.Place fans near constantly opening doors and shipping bays to produce and “air shield” effect that helps keep out cold air in winter and dust, odors and insects in the summer.

5.If desired, fans can be installed directly above heat producing machinery to reclaim the heated air.

6.For maximum air flow, fans should be located above aisles in warehouses and storage areas.

7.Make sure fan voltage is compatible with you electrical system.

HOW TO ASSEMBLE

MOUNTING

 

BRACKET

 

 

OUTLET BOX

 

UPPER CANOPY

 

SPRING WASHER

DOWN ROD

NUT

 

 

COTTER PIN

 

SPRING

 

WASHER

BUSHING

BOLT

SET SCREW

 

LOWER

 

CANOPY

 

LOCK

 

BOLT

 

 

BLADE

 

BLADE HOLDER

MOTOR UNIT

GASKET

FIGURE 1

 

GREEN

SUPPLY GROUND

GREEN

 

WHITE

SUPPLY NEUTRAL

BLACK

SUPPLY HOT

FIGURE 2

1.Locate down rod and remove spring bushing from hole in side of rod. Locate upper canopy and remove three screws holding fan mounting bracket in canopy. Place upper canopy over down rod with open end toward plastic ball hanger. Locate lower canopy and place over down rod with open end facing away from plastic ball hanger. Replace spring bushing into hole in side of down rod.

2.Feed white, black, and green supply wires from motor through the bushing in the down rod and up through the down rod.