INSTALLATION INSTRUCTIONS READ & SAVE THESE INSTRUCTIONS!

“OpenAire”

MODEL: PFOB-52

CAUTIONS

1.Before wiring the paddle fan, turn off the electric power supply at the main fuse or circuit breaker box and leave

it off until the installation is complete.

2.Mount the outlet box so it will support a minimum of

45pounds. The outlet box must be mounted flush to ceiling. Do not use a plastic outlet box.

3.Do not install paddle fan with less than 7 feet clearance between floor and lowest edge of fan blades.

4.If you are unfamiliar with electric wiring, acquire the services of a qualified electrician.

5.Use proper cable and fittings. Be certain the fan is properly grounded. Wiring must comply with national and local electrical codes.

6.Electrical requirements: 120vAC, 60 Hz, single phase,

1amp. – without optional lighting accessory.

7.Fan blades may be cleaned with a mild soap solution. Do not use an abrasive cleaner or a strong chemical cleaner.

8.WARNING: To reduce the risk of fire or electrical shock, do not use this fan with any solid-state speed control device (NOTE: Refer to NuTone's catalog for appropriate speed control switches.)

9.WARNING: To reduce the risk of personal injury, do not bend the blade brackets when installing the brackets, balancing the blades or cleaning the fan. Do not insert foreign objects between rotating fan blades.

10.CAUTION: To reduce the risk of electric shock, connect only to supply circuit provided with a ground fault circuit interrupter.

11.CAUTION: To reduce the risk of electric shock, fire or personal injury, a light kit must be marked suitable for use with this fan and must be marked as suitable for outdoor use.

12.Do not operate reversing switch while fan blades are in motion. Fan should be turned off and blades stopped before reversing blade direction.

LOCATION

1.Minimum ceiling height: 8 feet. When fan is installed, this allows a minimum of 7 feet between the floor and fan blades.

2.The center of the fan must be located at least 32" from any vertical surface.

3.Do not mount fan below, next to or between air ducts, beams or any other obstruction which may interfere with the natural air flow pattern created by the fan.

4.Fan can be mounted using down rod or closer to ceiling using ceiling cup as close up adapter.

MOUNTING ON A SLOPED CEILING

ALWAYS MOUNT HANGER

WITH OPENING TOWARD

TOP OF SLOPE

MINIMUM 1"

MAXIMUM

25°

FIGURE 1

HEADER

 

RUBBER

 

PADS

OUTLET BOX

 

SUPPLEMENTAL

SOCKET

MOUNTING SCREWS

HANGER

 

FIGURE 2

ceiling where the maximum angle of the sloped ceiling does not exceed 25°.

2.For any angled ceiling, use appropriate NuTone Extension Stems to insure proper clearance between the blades and ceiling. See NuTone catalog.

MOUNTING OUTLET BOX

Refer to Figure 2.

CAUTION: To reduce the risk of personal injury, install the supplemental mounting means and use only the hardware provided with the fan or use a listed outlet box marked as acceptable for fan support. If the combined weight of the ceiling fan and any light kit used with it exceeds 35 pounds, the fan should be supported independently of the outlet box. The weight of your fan is 20 lbs.

1.Fan mounts to a standard 4" metallic outlet box or a listed fan support box. For damp location mounting, use outlet box listed for “Damp Locations”. For outdoor mounting use outlet box listed for wet locations.

1.Refer to Figure 1. A paddle fan equipped with a ball and hanger bracket assembly can be safely mounted to a sloped

Page 1
Image 1
NuTone PFOB-52 installation instructions Location, Mounting on a Sloped Ceiling, Mounting Outlet BOX

PFOB-52 specifications

The NuTone PFOB-52 is a high-performance ventilation fan designed to enhance indoor air quality while providing a quiet and efficient operation. This model is particularly popular for residential bathrooms, kitchens, and other areas where proper ventilation is crucial. One of its standout features is the powerful fan motor that ensures effective air movement, effectively clearing moisture and odors from any space.

A key characteristic of the NuTone PFOB-52 is its ultra-quiet operation. With a noise level rated at just 0.7 sones, this fan is one of the quietest in its class. This makes it an excellent choice for bathrooms or homes where peace and tranquility are paramount, allowing users to run the fan without disturbing the serenity of their environment.

The design of the PFOB-52 is not only functional but also aesthetically pleasing. Its sleek and contemporary look allows it to blend seamlessly with most decors. The fan features a durable, stylish grille that contributes to its overall appeal while being easy to clean. This attention to design detail will ensure it enhances rather than detracts from the visual aspect of any room.

This model incorporates advanced technologies, including a robust motor designed for long-lasting performance. The PFOB-52 is also equipped with a unique air movement design that enhances airflow efficiency, contributing to energy savings over time. It offers up to 120 CFM airflow capacity, making it suitable for larger bathrooms or combined areas that require immediate and efficient air exchange.

Installation of the NuTone PFOB-52 is straightforward, making it a popular choice for DIY enthusiasts and professional installers alike. It features a compact housing that fits in standard ceiling structures and includes easy-to-follow instructions, reducing installation time and effort.

Moreover, the PFOB-52 complies with various energy efficiency standards, making it an environmentally friendly choice for homeowners looking to improve their indoor air quality without significantly increasing energy costs. With its blend of performance, quiet operation, and elegant design, the NuTone PFOB-52 ventilation fan stands out as a reliable solution for modern home ventilation needs.