8. TROUBLESHOOTING GUIDE

8. TROUBLESHOOTING GUIDE

PROBLEMS

POSSIBLE CAUSES

 

 

POSSIBLE REMEDY

 

1. Loss or

The plastic cap is not installed on

Place the included plastic cap on

decrease

 

the unused inlet.

 

 

 

the unused inlet opening.

 

of vacuum

Debris pail or disposable bag is

Change disposable bag or empty

occurs.

 

completely full.

 

 

 

debris pail as described on page 4.

 

 

 

 

 

NOTE: Clean secondary filter if

 

 

 

 

 

 

necessary.

 

 

• Obstruction in the hose. A blockage

• Disconnect the hose from the wall

 

 

in the hose can be determined by

 

inlet and insert a blunt instrument

 

 

inserting the hose into any wall

 

into the hose — slightly smaller in

 

 

inlet and, while power unit is

 

diameter — such as a flexible

 

 

running, check each additional

 

garden hose. Push the garden

 

 

inlet for normal suction by holding

 

hose through the cleaning system

 

 

the palm of your hand over the

 

hose until the obstruction has

 

 

open inlet. If normal suction is felt

 

been cleared.

 

 

 

at all other inlets, insert the hose

 

 

 

 

 

 

into a second inlet. If the blockage

 

 

 

 

 

 

still exists it is located in the hose.

 

 

 

 

 

 

However, if the blockage does not

 

 

 

 

 

 

occur when the hose is changed,

 

 

 

 

 

 

the blockage is probably located in

 

 

 

 

 

 

the tubing system leading to the

 

 

 

 

 

 

original inlet.

 

 

 

 

 

 

 

Obstruction in the tubing system

Insert hose end into any inlet with

 

 

inside the walls.

 

 

 

power unit running, place the palm

 

 

 

 

 

 

of your hand over the opposite

 

 

 

 

 

 

end of the hose. When you can

 

 

 

 

 

 

feel the suction increase, hold

 

 

 

 

 

 

your hand over the hose end for a

 

 

 

 

 

 

few seconds and then quickly

 

 

 

 

 

 

remove your hand. This procedure

 

 

 

 

 

 

repeated

several times

should

 

 

 

 

 

 

clear the

obstruction.

If the

 

 

 

 

 

 

blockage is not cleared, contact

 

 

 

 

 

 

your nearest Service Center.

 

• Wall inlet cover

not

properly

• Check all wall inlet covers to be sure

 

 

sealed.

 

 

 

they are closed and sealed tightly.

 

 

 

 

2. Power unit

Defective inlet. Check other wall inlets.

• Replace defective wall inlet.

does not

Power unit overcurrent

protector

• Turn the

unit off by using the

start or

 

has been activated.

 

 

power switch on the unit. Check

stops

 

 

 

 

 

the overcurrent protector

button

suddenly.

 

 

 

 

 

located on the left side of the

 

 

 

 

 

 

power unit (push to reset the

 

 

 

 

 

 

system). Turn unit back on.

 

• Blown fuse or

tripped circuit

• Replace fuse or reset circuit

 

 

breaker on house electrical panel.

 

breaker on house electrical panel.

 

Thermoprotector

has

been

• Turn the

unit off by using the

 

 

activated.

 

 

 

power switch on the unit. Wait

 

 

 

 

 

 

30 minutes to let the unit cool

 

 

 

 

 

 

down. Turn unit back on.

 

 

Defective hose.

 

 

• Replace hose as required.

 

 

 

 

 

3. Power unit

An electrical short has occurred

• A complete check of all wall inlets

fails to stop

 

somewhere in the system.

 

and power unit low voltage control

when the

 

 

 

 

 

leads connections.

 

hose is

 

 

 

 

 

Contact your authorized

Service

removed.

 

 

 

 

 

Center.

 

 

 

 

 

 

 

 

 

 

 

- 9 -