INSTALLATION INSTRUCTIONS

READ & SAVE THESE INSTRUCTIONS!

WhispAireRange Hood

WA6500 SERIES

! INTENDED FOR DOMESTIC COOKING ONLY !

IMPORTANT SAFETY INSTRUCTIONS

WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.

2.Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warn- ing device, such as a tag, to the service panel.

3.Installation work and electrical wiring must be done by a quali- fied person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and stan- dards.

4.Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code au- thorities.

5.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

6.Ducted fans must always be vented to the outdoors.

7.Use with approved cord-connection kit only.

8.To reduce the risk of fire, use only metal ductwork.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

1.Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ig- nite. Heat oils slowly on low or medium settings.

2.Always turn hood ON when cooking at high heat or when cooking flaming foods.

3.Clean ventilating fans frequently. Grease should not be al- lowed to accumulate on fan or filter.

4.Use proper pan size. Always use cookware appropriate for the size of the surface element.

IMPORTANT SAFETY INSTRUCTIONS

1.For general ventilating use only. Do not use to exhaust haz- ardous or explosive materials and vapors.

2.To reduce the risk of fire or electrical shock, this range hood should not be used with an additional speed control device.

3.To reduce the risk of shock, disconnect power before servicing.

4.To reduce the risk of fire and to properly exhaust air, be sure to duct air outside.

PLAN THE INSTALLATION

Recommended mounting height is 18” to 24” from the bottom of the range hood to the top of the cooking surface.

The hood should be mounted to the bottom of a standard wall cabinet. If the hood must be mounted directly to a wall, secure the hood to wall studs.

All wiring must comply with local codes and the unit must be prop- erly grounded. The hood is connected to a 110-120vAC lighting circuit (15 amp) in the circuit breaker or fuse box.

This range hood is “Convertible” – it may be installed as a ducted or as a non-ducted unit.

IF THE RANGE HOOD IS TO BE NON-DUCTED:

• Purchase non-ducted (duct-free) charcoal filter Model BPQTF.

IF THE RANGE HOOD IS TO BE DUCTED:

Ductwork can be installed vertically or horizontally.

Duct runs should be as short as possible.

Avoid the use of elbows.

Use duct tape at all joints.

Do not use duct smaller than the discharge on the hood.

For 7” round ductwork installation, use 7” round damper, Model 895 (purchased separately).

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOW- ING*:

1.SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PRE- VENT BURNS. If the flames do not go out immediately, EVACU-

ATE AND CALL THE FIRE DEPARTMENT.

2.NEVER PICK UP A FLAMING PAN - You may be burned.

3.DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result.

4.Use an extinguisher ONLY if:

A.You know you have a Class ABC extinguisher, and you already know how to operate it.

B.The fire is small and contained in the area where it started.

C.The fire department is being called.

D.You can fight the fire with your back to an exit.

* Based on “Kitchen Firesafety Tips” published by NFPA.

Page 1
Image 1
NuTone WA6500 installation instructions Important Safety Instructions, Plan the Installation

WA6500 specifications

The NuTone WA6500 is a cutting-edge bathroom exhaust fan that combines innovative technology with elegant design, making it a standout choice for homeowners looking to enhance their bathroom's air quality and aesthetics. This model is designed specifically to eliminate humidity, odors, and pollutants, thereby ensuring a fresher and healthier environment.

One of the main features of the WA6500 is its powerful yet efficient motor. With a strong airflow rating, it can effectively vent large bathrooms quickly, reducing moisture levels that can lead to mold and mildew growth. The fan operates quietly, providing a soothing atmosphere without the disruptive noise often associated with traditional exhaust fans. This is a significant advantage for users seeking peace and tranquility while engaging in their daily routines.

The WA6500 is equipped with advanced technology, including a built-in humidity sensor that automatically activates the fan when moisture levels exceed a preset threshold. This smart feature helps to maintain a consistent level of humidity in the bathroom, ensuring that the space remains dry and comfortable.

Another notable aspect of the NuTone WA6500 is its stylish design. The fan features a sleek and modern appearance, seamlessly integrating into various bathroom decors. Available in different finishes, it allows homeowners to choose an option that best matches their aesthetic preferences.

Installation is made easier with the WA6500, as it comes with a flexible duct connection and a mounting template, allowing for a hassle-free setup process. The fan is also compatible with different ceiling types and can be retrofitted into existing installations, giving homeowners flexibility in upgrading their ventilation systems.

Energy efficiency is a priority for the WA6500, as it meets or exceeds ENERGY STAR requirements. This makes it an environmentally friendly option, reducing electricity consumption and lowering utility bills over time.

Overall, the NuTone WA6500 is an exceptional bathroom exhaust fan that not only enhances indoor air quality but also adds an element of sophistication to any space. Its combination of power, efficiency, and stylish design makes it an outstanding choice for modern bathrooms, ensuring a comfortable and fresh environment for all users.