NuTone WS2 manual For Domestic Cooking only, Table of Contents

Models: WS2

1 16
Download 16 pages 39.77 Kb
Page 1
Image 1

®

ALLURE® WS2 SERIES RANGE HOOD

ALLURE® WS2 SERIES

RANGE HOOD

Page 1

Patent No.:

US D450, 829 S

READ AND SAVE THESE INSTRUCTIONS

! FOR DOMESTIC COOKING ONLY !

WARNING

 

CAUTION !

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.

2.Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means can- not be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

3.Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, in- cluding fire-rated construction codes and standards.

4.Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

5.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

6.To reduce the risk of fire or electric shock, do not use this range hood with an additional speed control device.

7.Ducted fans must always be vented to the outdoors.

8.To reduce the risk of fire, use only metal ductwork.

9.Use with approved cord-connection kit only.

10.This unit must be grounded.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

1.Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

2.Always turn hood ON when cooking at high heat or when cooking flaming foods.

3.Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.

4.Use proper pan size. Always use cookware appropriate for the size of the surface element.

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*

1.SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.

2.NEVER PICK UP A FLAMING PAN — You may be burned.

3.DO NOT USE WATER, including wet dishcloths or towels - violent steam explosion will result.

4.Use an extinguisher ONLY if:

A.You know you have a Class ABC extinguisher and you already know how to operate it.

B.The fire is small and contained in the area where it started.

C.The fire department is being called.

D.You can fight the fire with your back to an exit.

*Based on “Kitchen Fire Safety Tips” published by NFPA.

1.For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

2.To avoid motor bearing damage and noisy and/or unbalanced impel- lers, keep drywall spray, construction dust, etc. off power unit.

3.For best capture of cooking impurities, your range hood should be mounted so that the top of the hood is 24-30” above the cooking surface.

4.Please read specification label on product for further information and requirements.

Installer: Leave this manual with the homeowner.

Homeowner: Operating and Cleaning information on page 6.

NOTE

If hood is to be installed Non-Ducted:

 

Purchase a set of (2) non-ducted filters from your

 

 

local distributor or retailer and attach them to the

 

 

aluminum mesh filters.

TABLE OF CONTENTS

This manual is divided into sections as follows:

“PREPARE HOOD LOCATION”

Run ductwork from roof or wall cap, and electrical wiring from service panel - to installation location

“PREPARE THE HOOD”

Get your hood ready for installation

“CONNECT WIRING”

Make electrical wiring connections to hood

“INSTALL HOOD”

Secure hood to cabinet and ductwork - install bulbs and filters

“OPERATION”

How to use the hood controls

“CLEANING”

Keep your hood in top working condition

“SERVICE PARTS”

Part numbers and exploded view of hood components

“WARRANTY”

One-year limited warranty and how to contact us

Page 1
Image 1
NuTone WS2 manual For Domestic Cooking only, Table of Contents

WS2 specifications

NuTone WS2 is a state-of-the-art wireless intercom system designed to enhance communication and convenience within a home. This innovative device seamlessly integrates advanced technologies and user-friendly features, making it a valuable addition to any modern household.

One of the main features of the NuTone WS2 is its wireless connectivity, which eliminates the need for cumbersome wiring. This allows users to place intercom units in various locations throughout the home without the hassle of installation complications typically associated with wired systems. The WS2 operates on a reliable frequency, ensuring clear audio transmission and minimal interference from other electronic devices.

The WS2's crystal-clear sound quality is one of its standout characteristics. Equipped with high-fidelity speakers, it provides crisp and clear audio, which is essential for effective communication. Whether users are talking from one room to another, checking in with family members, or broadcasting messages, the sound remains consistent and is easily understood.

Another significant technology incorporated into the NuTone WS2 is its user-friendly interface. With a simple touch-sensitive keypad, users can navigate through various functions, such as initiating a conversation, adjusting volume levels, and selecting different pre-set channels. This intuitive design ensures that individuals of all ages can operate the system effortlessly.

Additionally, the WS2 is equipped with a dedicated mobile app, which enhances its functionality. This innovative feature allows homeowners to communicate with the intercom system remotely via their smartphones. Users can receive alerts, make announcements, and even engage in conversations from anywhere within their Wi-Fi range, turning their mobile devices into effective communication tools.

The NuTone WS2's sleek, modern design fits seamlessly into contemporary home décor. Its compact form factor and aesthetically pleasing finish ensure that it complements the interior while remaining functional. Furthermore, the flexible mounting options allow users to choose their preferred setup, whether wall-mounted or placed on a countertop.

Security is also a key consideration in the design of the WS2. The system includes features to enhance home safety, such as the option to connect to existing security systems, ensuring that communication is not just limited to intercom tasks but also contributes to overall home monitoring.

In summary, the NuTone WS2 is a versatile and modern intercom system that combines wireless technology, exceptional sound quality, and user-friendly features. Its innovative design and capabilities make it an excellent choice for enhancing communication within any household.