OK International DX-250 Features, Symbol Definitions, 3SPECIFICATIONS, Items, Description

Models: DX-250

1 15
Download 15 pages 51.01 Kb
Page 2
Image 2
FEATURES

The fluid being dispensed may be toxic and/or hazardous. Refer to Material

4

FEATURES

Safety Data Sheet for proper handling and safety precautions

 

 

If a piston is not used with the barrel, an inline filter (881-000-000) must be

 

 

 

installed on the receiver head to help prevent fluids from being sucked back

 

 

into the unit. Also do not overfill the barrel and to lay the barrel on its side

 

 

Do not smoke or use open flame when flammable materials are being dispensed

 

 

This equipment is for indoor use only

 

10

 

 

 

2 SYMBOL DEFINITIONS

2

4

 

 

12

13

Symbol

Definition

 

Power On/Off

 

Cycle Mode

 

Timer

 

Vacuum

 

Pressure

 

 

11

 

3

 

1

 

16

 

 

 

5

 

9

6

15

8

7

 

 

 

14

3SPECIFICATIONS

Size

152mm X 165mm X 178mm

(6” X 6.5” X 7”)

 

Weight

1.2 kg (2.6lbs)

Input Voltage

24 VDC

Rated Power

10 W

Air Input

100 psi (6.9 bar) Max.

Pollution Degree

II

Installation Category

I

Indoor Use

Altitude up to 2,000m (6,562ft)

Operating Temperature

0˚C to 50˚C (32˚F to 122˚F)

Storage Temperature

-10˚C to 60˚C (14˚F to 140˚F)

Max. Relative Humidity

80% for temperature up to 31˚C (87.8˚F) Decreasing

linearly to 50% relative humility at 40˚C (104˚F)

 

 

 

Air Output

DX-250 = 0-100 psi (0-6.9 bar)

DX-255 = 0-15 psi (0-1.03 bar)

 

Vacuum

406mm (16”) of Hg

Timer

0.020 – 60.000 seconds

Cycle Mode

Manual, Timed

Timing Repeat Tolerance

+/- 0.001%

Cycle Rate

600 cycles/min

LCD

16 X 2 display segments

 

3

 

Figure 1.0

 

 

Items

Description

1

Power Button

2

Mode Button

3

Counter Reset Button

 

 

4

Display

 

 

5

Air Pressure Gauge

6

Air Pressure Regulator

 

 

7

Pulsed Air Outlet

 

 

8

Vacuum Control

 

 

9

Time Control Knob

10

Receiver head air hose holder

 

 

11

Foot Switch Receptacle

 

 

12

Power Receptacle

 

 

13

I/O Connection

14

Exhaust Port

 

 

15

Air Inlet

 

 

16

Cord Lock

4

Page 2
Image 2
OK International DX-250 specifications Features, Symbol Definitions, 3SPECIFICATIONS, Items, Description