Page 5

Caution: Follow these instructions to avoid failure.

Danger: Wear eye protection when installing or removing flowmeter.

1.Polysulfone and other exotic plastics cannot tolerate PVC Glue and /or pipe dope. even fumes can cause crazing.

2.If you are installing your flowmeter to

a glued pipe configuration, install flowmeter after all glued fittings are dried and lines are purged of all fumes.

Use Teflon® tape (or similar) for the flowmeters threaded adapters.

Hand tighten union nuts. No wrenches.

3.Wall, floor, and ceiling mounts are to be carefully aligned and sturdy. Wall, floor, and ceiling supports are recom- mended as needed.

Ceiling

3

1

2

 

3

 

3

4

5

Floor

4.Valves - Avoid a system that will impose a sudden burst of flow to the meter. Such a burst will cause the float to impact the float stop with destructive force. Magnet, solenoid, or other quick opening valves cannot be used unless meter is protected against sudden bursts of flow.

5.The maximum working pressure should not exceed 150 psi at ambient temperature.

Maximum Temperature vs. Pressure

Temperature

200°F / 93.3°C 190°F / 87.8°C 180°F / 82.2°C 170°F / 76.7°C 160°F / 71.1°C

150°F / 65.6°C

140°F / 60.0°C 130°F / 54.4°C 120°F / 48.9°C 110°F / 43.3°C 100°F / 37.8°C

90°F / 32.2°C 80°F / 26.7°C

70°F / 21.1°C

0 / 0

25 / 1.7

50 / 3.4

75 / 5.2

100 / 6.9

125 / 8.6

150 / 10.3

PSIg / BAR

Page 6
Image 6
Omega FL45200A manual Maximum Temperature vs. Pressure