Omega Engineering LVU-90 warranty Specifications, About Ultrasonic Technology, Step One

Models: LVU-90

1 6
Download 6 pages 31.26 Kb
Page 2
Image 2
SPECIFICATIONS

SPECIFICATIONS

Step One

Range:

3.6" to 6' (9 cm to 1.8 m)

Accuracy:

± .25% of span in air

Resolution:

0.125” (3 mm)

Frequency:

83 kHz (nominal)

Pulse rate:

2 pulses per second

Beam width:

8° conical

Dead band:

3.6” (9 cm)

Supply voltage:

12-36 VDC

Max loop resistance:

600 Ohms @ 36 VDC

Signal output:

4-20 mA, 12-36 VDC

Fail-safe diagnostics: Reverts to 22 mA

 

LED flashing

Temperature rating:

F: -40º to 140º

 

C: -40º to 60º

Temp. compensation: Automatic over entire range

Pressure rating:

30 psi (2 bar) @ 25 °C., derated @ 1.667 psi

 

(0.113 bar) per °C. above 25 °C.

Enclosure rating:

NEMA 4X / IP65

Enclosure material:

Polypropylene, U.L. 94VO

Transducer materials: PVDF

Mounting threads:

3/4” NPT for LVU-91

 

3/4” G for L VU-92

Mounting gasket:

Viton (3/4" G) LVU-92 only

Conduit connection:

1/2” NPT

CE compliance:

EN 50082-2 immunity

 

EN 55011 emission

 

(pending)

 

 

About Ultrasonic Technology:

An ultrasonic sound wave is pulsed five times per second from the base of the transducer. The sound wave reflects against the process medium below and returns to the transducer. The microprocessor based electronics measures the time of flight between the sound gen- eration and receipt, and translates this figure into the distance between the transmitter and process medium below.

 

POWER

(-)

(+)

GND

12-36 VDC

4-20 mA

6’ Range

 

 

 

8° Cone

 

 

 

Radius

 

 

 

 

 

 

 

Range

Radius

Radius

 

Feet

Inches

cm

 

 

 

 

 

1

1 . 2

3 . 1

 

2

2 . 1

5 . 2

 

3

2 . 9

7 . 3

 

4

3 . 7

9 . 5

 

5

4 . 9

11 . 6

 

6

5 . 4

1 3 . 7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum Temperature/Voltage Derating

 

 

 

35

Temperature/Pressure Derating

 

100

Continuous 20 mA Curve

 

 

700

 

 

 

Unacceptable

 

 

 

 

 

 

 

 

30

 

 

 

 

 

 

 

 

 

 

600

Operating Pressure(psi)

 

 

 

Range

AmbientSensorTemperatureC)°(

80

Unacceptable

 

 

 

Max.Series Resistance(Ohms)

25

 

 

 

 

 

Range

 

 

 

500

 

 

 

 

60

 

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

400

Acceptable

 

 

 

 

 

 

 

 

 

 

 

 

40

 

Acceptable

 

 

 

300

15

 

Range

 

 

 

 

 

 

10

 

 

 

 

 

 

 

Range

 

 

 

200

 

 

 

 

20

 

 

 

 

 

 

05

 

 

 

 

 

 

 

 

 

 

100

 

 

 

 

0

 

 

 

 

 

 

00

 

 

 

 

 

 

 

 

 

 

000

-20

00

20

40

12

16

20

24

28

32

36

 

-40

60

 

 

 

 

 

 

 

 

 

Temperature (°C)

Operating Voltage (VDC)

 

Electrical Loading Limits

Unacceptable

Range

Acceptable

Range

18

24

30

36

Supply Volyage (VDC)

Page 2
Image 2
Omega Engineering LVU-90 warranty Specifications, About Ultrasonic Technology, Step One