5Specifications
SECTION 5 – SPECIFICATIONS
5.1 - General
Temperature Range: |
|
0 to 100ºC (32 to 212ºF) | |
Accuracy: @22ºC (72ºF) ambient 1.5% of Rdg or 2.0ºC (3.5ºF) whichever is greater
Emissivity of 0.95 or greater
Repeatability:
Field of View:
Spectral Response:
Response Time:
Emissivity:
Alarm Output:
Alarm Set Point:
Analog output:
MA
V1
V2
K
MVC
MVF
Output Load Requirements:
Min. Load (0 to 5 Vdc)
Min. Load (0 to 10 Vdc)
Max. Load (4 to 20 mA)
Min. Load (10 mV/Deg)
Min. Load (K T/C)
Operating Ambient Temperature:
No Water Cooling
With Water Cooling
Operating Relative Humidity: Water Flow Rate for
Thermal Shock:
1% of Rdg or 1.0ºC (2.0ºF) whichever is greater
10 to 1
8 to 14 microns
150 msec, 0 to 63% of final value
0.5to 1.0, adjustable via Single Turn Pot Voltage, 100 mA Drive
0 to 100% Adj., set via Pot
4 to 20 mA
0 to 5 Vdc
0 to 10 Vdc
K type thermocouple, compensated
10mV/ºC
10mV/ºF
2
4
(Power Supply – 4)/20 mA
10
100
0 to 70ºC (32 to 158ºF)
0 to 200ºC (32 to 392ºF)
0 to 110°C (32 to 230°F)
Less than 95% RH,
0.25GPM, room temperature, minimum 5 CFM (2.4 liters/sec)
1 to 2 minutes
About 30 minutes for 25ºC (77°F) abrupt ambient temperature change
Air Flow Rate for Air Purge Collar 1 CFM (0.5 liters/sec.)
Transmitter Housing: | Stainless Steel 316, |
Power: | 12 to 24 VDC @ 50 mA |
Dimensions: | 25.4 OD x 127 L mm (1.0" OD x 5.0" L) |
Weight: | 0.80 lb (363 g) |