Omega Speaker Systems LVUC10, LVU-260, LVU-230 Final Installation, Contact Models, Control Unit

Models: LVU-230 LVUC10 LVU-260

1 16
Download 16 pages 12.25 Kb
Page 7
Image 7

 

 

 

 

FINAL INSTALLATION

3

 

 

CONTACT MODELS

Follow the instructions below:

1.Drill a suitable hole in the vessel or pipe wall and tap for 3/4” NPT. If this walled vessel or material is not suitable for threading, weld or braze a bush- ing to accept the sensor.

2.Screw the sensor in the threaded section and make sure that there is a good seal. Use a pipe compound or sealing tape compatible with the materials and avoid excessive tightening.

3.Run the power and control wiring cable to the electronic control unit. Observing all applicable electrical codes and proper wiring procedures.

CONTROL UNIT

Refer to the typical installation diagram and control unit dimensions when installing the control unit. Follow steps 1 and 2 below for remote mounted elec- tronic units. Steps 3 through 7 are common for both the integral electronic units and remote electronic units.

1.Mount the remote control unit on any suitable wall, panel, etc. making sure there is adequate clearance for wiring.

2.Remove the PC board by removing the screws. Drill a suitable size hole in the control unit housing for a conduit fitting (if so required).

3.Remove the cover from housing. To complete wiring, either leave or remove the electronics printed circuit board in the housing on remote units and remove the encapsulate electronics in integral units.

CAUTION: Never remove unit from a vessel with power and/or output control cables connected to the electronic control unit inside the housing to avoid cable damage.

4.Wire the unit as desired. Refer to the wiring diagram inside the cover.

Note: All wiring, conduit and fittings should conform to local electrical codes. In a hazardous location, a conduit seal should be installed within 18 inches of the control unit housing. Use a drain seal in vertical conduit run to prevent condensation from entering the control unit. OMEGA assumes no responsibility for improperly wired units.

5.Replace the printed circuit board, if removed, or the encapsulated electronics. Make certain that the wires are dressed carefully to prevent pinching between the cover and the housing.

6.Replace the housing cover.

6For Ultrasonic Point Level Switches

Page 7
Image 7
Omega Speaker Systems LVUC10, LVU-260, LVU-230 manual Final Installation, Contact Models, Control Unit