Enabling the Front Panel Reset Key
The fourth screen in the program mode allows you to enable or disable the front panel reset key.
Press the m key to choose the option you want.
Note: The reset terminal on the rear panel is still active when the front reset button is disabled.
Note: To exit the program mode, disconnect the jumper between terminals 1 and 5.
WIRING RECOMMENDATIONS
Following these suggestions will increase noise immunity and lengthen unit life.
Cable: Make the connection between the count source and the totalizer with a
Relay Coil Suppression: If a relay contact is used as a count source, suppress the relay coil. This can be accom- plished with an RC network for AC coils or a diode for DC coils.
Mounting: Do not mount the totalizer near a solenoid or other inductive devices. Supply enough ventilation to keep the totalizer operating within the temperature specifications. Do not mount this unit in a heavy vibration area.
WIRING DIAGRAMS
SOLID STATE ADD/SUBTRACT INPUT
CURRENT SOURCING SENSOR
SOLID STATE ADD/SUBTRACT INPUT
CURRENT SINKING SENSOR
+6 to +28 VDC
,
Sensor
CONTACT CLOSURE COUNT INPUT
PROGRAM MODE ENABLE (All Models)
REMOTE RESET (All Models)
[_Zk
BATTERYSAFETY
The lithium battery that powers your device contains inflam- mable materials such as lithium organic solvent, and other chemical ingredients. Explosion or fire may result if the battery is not handled correctly. To avoid an accident follow these guidelines:
??Do not heat batteries above 95°C
??Do not recharge lithium batteries
??Do not dispose of batteries in fire
??Insert battery with correct polarity
Terminal Function
1Ground
2Input B Count input
3Input A Count Input
4Reset
5Program Enable
Operation
Current Source Input
Current Source Input
Connect through Contact
Closure to Ground
Connect to Ground to Enter Program Mode
Page 4