DPCI 0-TL Totalizer
Ml 662/0693
k- 2.95” (74.93mm) |
| 2.677” (68mm) |
|
| ||
I | I T | < |
| |||
Recommended | ||||||
| 1.57 |
| Panel Cutout |
| 1.299” | |
| (39.87mm) |
|
| (33mm) | ||
| 1 | I |
| I | __!I |
POWER
Internal battery: 3 V, lithium
Life expectancy: 5 years +
Replacement Pan:
PHYSICAL
Operation Temperature: 0” - 55°C
Storage Temperature:
Operating Humidity: 90%
Weight: 2.2 oz. net
Display Size: .43” high
Front Panel Rating:
Case Material: Cycolac X-17
TOTALIZER
Type: UP counting
Digits: 8
DC COMMON (Terminal 1)
COUNT INPUTS
Input B (Terminal 2) low speed input designed for contact closures to common
Speed:
Minimum Low Time: 5msec
Minimum High Time: 20msec
Impedance: 101 kR
Voltage Thresholds: Low 0 to 0.4 V dc
High 2.0 to 28 V dc
Max. High 28 V dc
lnputA(Terminal3) highspeedinputrequiringavoltagesource such ee a current sourcing sensor or a current sinking sensor used with the provided pull up resistors.
Speed: 0 to 10 kHz
Minimum Low Time: 80 microseconds
Minimum High Time: 20 microseconds
(The above times are with a 0 to 5.0 V swing.) Input Impedance: 2kS2 above 5 V dc Voltage Thresholds: Low 0 to 1.2 V dc
High 2.0 to 28 V dc
Max. High 28 V dc
RESET INPUT (Terminal 4) designed for contact closures to dc common.
Minimum Low: 0.25 to 1 second (maintained)
The required pulse width varies with count speed, scale factor and number of digits displayed.
Voltage Thresholds: Low 0 to 0.4 V dc High 2.0 to 28 V dc
FRONT PANEL RESET ENABLE (Terminal 5)
Operation: Level sensitive (maintained)
COUNT ACCURACY
100% when operated within specifications.