MADE
IN
USA WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA s customers receive maximum coverage on each product.
If the unit should malfunction, it must be returned to the factory for evaluation. OMEGAs Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective it will be repaired or replaced at no charge. OMEGA’S WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGAs control. Components which wear are not warranted, including but not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use if its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects.
OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it
be used: (1) as a Basic Component under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY / DISCLAIMER language, and additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
RETURN REQUESTS / INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
6
9.Start the configuration program, you need to indicate which serial port is to be used for serial communication by checking the appropriate check box on the opening menu.
Note: It is not necessary to know the serial communication protocol. i.e. baud rate, parity, 7/8 data bit and stop bit; the program will determine this information automatically. However, it is good practice to mark the protocols used on the signal conditioner label if different from default.
10.Once the program starts it will automatically detect the signal conditioner configuration and will display a window of available options. To view the signal input click on the display on/off.
11.To change analog output scaling choose analog output scaling and enter the desired values.
12.Once the custom scaling is finished, ensure that Send Configuration is clicked, otherwise the changes will not take effect.
13.The input/output scaling may be fine tuned, while both communication and analog output are active. You may make a change to the analog output in the configuration program, and watch the DVM connected to analog output of the signal conditioner follow the new settings.
14.You may save or print a particular configuration by selecting the file menu. ItÕs always a good practice to both print and save the scaling of each signal conditioner.
15.If the program is not able to establish communication then an error message is displayed. This happens either when the wrong serial port is specified or when the cable is disconnected.
MADE
IN
USA
DRN-ACC
AC Current Signal Conditioner
| | | ® |
| | | ® |
| | |
OMEGAnet¨ On-Line Service | | Internet e-mail |
www.omega.com | | info@omega.com |
| Servicing North America: |
USA:•• | One Omega Drive, P.O. Box 4047 |
ISO 9001 Certified• | Stamford CT 06907-0047 | |
•• | TEL: (203) 359-1660•• | FAX: (203) 359-7700 |
••e-mail: info@omega.com
••Laval (Quebec) H7L 5A1
•• | TEL: (514) 856-6928•• | FAX: (514) 856-6886 |
••e-mail: info@omega.ca
For immediate technical or application assistance:
USA and Canada:• Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA¨
••Customer Service: 1-800-622-2378 / 1-800-622-BEST¨
••Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN¨
••TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA
Mexico and • | TEL: (001)800-TC-OMEGA¨• | FAX: (001) 203-359-7807 |
Latin American:• | En Espa–ol: (001) 203-359-7803• | |
••e-mail: info@omega.com.mx
Servicing Europe: