HH506RA
K, J, T, E, R, S, N Thermometer
OMEGAnet® | Internet |
omega.com | info@omega.com |
|
|
INTRODUCTION
The HH506RA is a portable digital thermometer that measures external thermocouples of type K, J, R, S, T, E, and N. The thermocouple types comply with the NIST- ITS 90 standard reference temperature/voltage tables. The thermometer features a dual thermocouple input, an adjust-
ENVIRONMENTAL
Ambient Operating Ranges:
0C to 50C (32F to 122F) <80% R.H.
StorageTemperature:
InputConnector:
INSTRUCTION
M4079/0704
Servicing North America:
U.S.A.: One Omega Drive, Box 4047 |
able T/C offset and an
Accepts standard miniature thermocouple connectors (flat blades spaced 7.9 mm, center to center).
SHEET Shop online at: omega.com
HH506RA MULTILOGGERTHERMOMETER
|
| Stamford, CT |
|
ISO 9001 | Tel: (203) | FAX: (203) | |
Certified |
|
| |
Canada: | 976 Bergar |
| |
|
| Laval (Quebec) H7L 5A1, Canada | |
|
| Tel: (514) | FAX: (514) |
|
|
|
For immediate technical or application assistance:
U.S.A. | Sales Service: | |
and | Customer Service: | |
Canada: | Engineering Service: | |
| TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA | |
Mexico: | En Espan˜ol: (001) | |
| FAX: (001) | info@omega.com.mx |
| Servicing Europe: | |
Benelux: Postbus 8034, 1180 LA Amstelveen, The Netherlands | ||
| Tel: +31 (0)20 3472121 | FAX: +31 (0)20 6434643 |
| Toll Free in Benelux: 0800 0993344 | |
|
| |
Czech | Frystatska 184, 733 01 Karviná, Czech Republic | |
Republic: Tel: +420 (0)59 6311899 | FAX: +420 (0)59 6311114 | |
| Toll Free: | |
France: | 11, rue Jacques Cartier, 78280 Guyancourt, France | |
| Tel: +33 (0)1 61 37 2900 | FAX: +33 (0)1 30 57 5427 |
| Toll Free in France: 0800 466 342 | |
|
|
Germany/ Daimlerstrasse 26,
Toll Free in Germany: 0800 639 7678
United One Omega Drive, River Bend Technology Centre
Kingdom: Northbank, Irlam, Manchester ISO 9002 M44 5BD United Kingdom
Certified Tel: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622
Toll Free in United Kingdom:
It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.
WARNING: These products are not designed for use in, and should not be used for, human applications.
SAFETY INFORMATION
To avoid electrical shock do not use the device when the working voltages exceed 24V AC or DC. To avoid damages to the instrument and/or physical burns, do not make measurements in microwave ovens. Avoid sharp bending of the thermocouple leads to prolong its life, especially near the connector.
WARNING
To avoid electrical shock, do not use this instrument when working voltages at the measurement surface
are over 24V AC or DC.
WARNING
To avoid damage or burns, do not take temperature measurements in microwave ovens.
CAUTION
Repeated sharp flexing can break the thermocouple leads. To prolong lead life, avoid sharp bends in the leads, especially near the connector.
GENERAL
Displays:
The Main and Second display panels are 4 1/2 digit liquid crystal display (LCD) with maximum reading of 19999. These panels are used for displaying the value of T1 or T2. The Third panel displays the date, time, or the difference value of T1 to T2. When the input measurement is overloaded, the following is displayed “
Battery:
Standard 9V battery (NEDA 1604, IEC 6F22 006P) Battery life is about 100 hours when used with a carbon zinc battery.
Dimensions:
192 mm (H) x 91 mm (W) x 52.5 mm (D) Weight: 365 g
SuppliedWire:
4 feet Type “K” thermocouple beaded wire (teflon tape insulated). Maximum insulation temperature 260C (500F). Wire accuracy 2.2C or 0.75% of reading (whichever is greater) from 0C to 800C.
SPECIFICATIONS
ELECTRICAL
Temperature Scale: Celsius or Fahrenheit
MeasurementRange:
| |
| |
| |
| |
0C to 1767C, | |
| 32F to 3212F |
0C to 1767C, | |
| 32F to 3212F |
|
*Based on the
K/J/T/E-TYPE
(0.05% rdg + 0.3C) on
N-TYPE
(0.05% rdg + 0.8C) on
(0.05% rdg + 0.4C) on 0C to 1300C
(0.05% rdg + 1.6F) on
(0.05% rdg + 0.8F) on 32F to 2372F
(0.05% rdg + 2C) on 0C to 1767C
(0.05% rdg + 4F) on 32F to 3212F
TemperatureCoefficient:
0.1times the applicable accuracy specification per C from 0C to 18 and 28C to 50C (32F to 64F and 82F
to 122F)
InputProtecion:
24V dc or 24V ac rms maximum input voltage on any combination of input pins.
Reading Rate: 2.5 time per second.