(10)“TYPE”button(MAIN)

Press this button to change the type of thermocouple in the main display (K/J/T/E/R/S/N). If the inputs of the main and second displays are the same, then pressing this button will change the thermocouple type for both displays.

(11)“TYPE”button(SECOND)

Press this button to change the type of thermocouple in the second display (K/J/T/E/R/S/N). If the inputs of the main and second display are the same, then pressing this button will change the thermocouple type for both displays.

SETUPMODE

The following functions can only be used in the setup mode.

(2)“[Limits]”button(Hi/Lolimitsetting)and

MiniDINoutput

Press the LIMITS button to enter the Hi/Lo Limit setup function, the “LIMIT”, “HI”, and main display will blink on the LCD, and the previous settings are displayed. Press the number button printed on the overlay in white to

set Hi or Lo limit value. the resolution of Hi/Lo limit setup is 1 count. The button “-” (same button as the ESC) can be used to set negative values. Setting is from left to right digit. Press the “ENTER” button to confirm each setting.

3)“[INVT]”button(Intervaltimesetting)

To setup the time interval for the log function, press the [INVT] button to set the time. The indicator “INV” will be blinking on the topright of the LCD and the previous settings will be displayed. Press the number button printed on the overlay in white to change the time interval. Setting is from left to right of the following format (HH:MM:SS). Press the overlay “ENTER” button to confirm. To exit this function, press the ESC button.

HH: Interval Hour (0~23)

MM: Interval Minute (0~59)

SS: Interval Second (0~59)

MAX: 23:59:59

MIN:00:00:01

(9)“[OFS]”button(Thermocoupleoffsetadjust)

When the main display input is T1 and socket thermo- couple is connected, the instrument can adjust the offset of the thermocouple or vice-versa for T2. In the setup mode, press this button to enter the thermocouple Offset Setup Function (OFS) and the indicator CAL should be displayed on the top righthand corner of the LCD while the main display blinks. While the previous setting is displayed, press the Number button printed on the overlay in white to change or set the offset of the thermocouple. The resolution of the setup is 0.1. Press the “-” button to set the negative value. Press the overlay “ENTER” button to confirm. MAX: 1999.9 C/F

(12)“[TIME]”button(Systemdateandtimesetting)

To set or change the system time, press the [TIME] button in the setup mode. The time and date on the third display panel should blink. Enter from left to right in the following format: YY:MM:DD and HH:MM:SS. Press the Number button printed on the overlay in white word to set the system date and time. Press the “ENTER” button to confirm. Exit this function by pressing the ESC button.

PROCEDUREOFCALIBRATION

1.Make ADJ pin short.

2.T2 input for a voltage of 70mV will show a value higher than 28000 2dgts at the third display and then press “set[]” key in the next step.

3.T1 input for a temperature of 0C will show a value

5C at the main display. Press “set[]” key to complete the calibration.

4. Take off the short pin.

OPERATORMAINTENANCE

WARNING

To avoid possible electrical shock, disconnect the thermocouple connectors from the thermometer before removing the cover.

WARRANTY/DISCLAIMER

OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1)

year product warranty to cover ling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.

If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’ s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs.

OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND

WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.

CONDITIONS: Equipment sold by OMEGA is not intended to be

used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY / DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.

RETURN REQUESTS / INQUIRIES

Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’ S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.

The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.

Where Do I Find Everything I Need

for Process Measurement

and Control?

OMEGA…Of Course!

Shop online at omega.com

TEMPERATURE

☐✔ Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies

☐✔ Wire: Thermocouple, RTD & Thermistor ☐✔ Calibrators & Ice Point References

☐✔ Recorders, Controllers & Process Monitors ☐✔ Infrared Pyrometers

PRESSURE, STRAIN AND FORCE

☐✔ Transducers & Strain Gages ☐✔ Load Cells & Pressure Gages ☐✔ Displacement Transducers ☐✔ Instrumentation & Accessories

FLOW/LEVEL

☐✔ Rotameters, Gas Mass Flowmeters & Flow Computers

☐✔ Air Velocity Indicators

☐✔ Turbine/Paddlewheel Systems ☐✔ Totalizers & Batch Controllers

pH/CONDUCTIVITY

☐✔ pH Electrodes, Testers & Accessories ☐✔ Benchtop/Laboratory Meters

☐✔ Controllers, Calibrators, Simulators & Pumps ☐✔ Industrial pH & Conductivity Equipment

DATA ACQUISITION

☐✔ Data Acquisition & Engineering Software ☐✔ Communications-Based Acquisition Systems ☐✔ Plug-in Cards for Apple, IBM & Compatibles ☐✔ Datalogging Systems

☐✔ Recorders, Printers & Plotters

HEATERS

☐✔ Heating Cable

☐✔ Cartridge & Strip Heaters

(8) “[APO]” button (Auto power off /time setting,

min.5minutes)

Use this function to change the time for the Auto Power

Off (APO) function. Press the [APO] in setup mode, and the

indicator “APO” and the main display will blink on the

LCD, and the previous setting will be displayed. The

default time for APO is 5 minutes. Press the Number button

BatteryReplacement

Power is supplied by a 9 volt “transistor” battery. (NEDA 1604, IEC 6F22). The “ ” appears on the LCD display when replacement is needed. To replace the bat- tery, remove the two screws from the back of the meter and lift off the battery cover. Remove the battery from battery contacts.

FOR WARRANTY RETURNS,

please have the following information available BEFORE contacting OMEGA:

1.Purchase Order number under which the product was

PURCHASED,

2.Model and serial number of the product under warranty, and

3.Repair instructions and/or specific problems relative to the product.

FOR NON-WARRANTY

REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:

1.Purchase Order number to cover the COST of the repair,

2.Model and serial number of the product, and

3.Repair instructions and/or specific problems relative to the product.

☐✔ Immersion & Band Heaters ☐✔ Flexible Heaters

☐✔ Laboratory Heaters

ENVIRONMENTAL MONITORING AND CONTROL

☐✔ Metering & Control Instrumentation ☐✔ Refractometers

☐✔ Pumps & Tubing

printed on the overlay in white to set the APO time.

Press the overlay “ENTER” button to confirm. To exit this

function without changing the setting, press the ESC

button.

MAX: 19999 minutes

MIN: 0005 minutes

OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering.

OMEGA is a registered trademark of OMEGA ENGINEERING, INC. © Copyright 2004 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.

☐✔ Air, Soil & Water Monitors

☐✔ Industrial Water & Wastewater Treatment

☐✔ pH, Conductivity & Dissolved Oxygen Instruments

Page 3
Image 3
Omega Vehicle Security HH506RA 10TYPEbuttonMAIN, 11TYPEbuttonSECOND, 2LimitsbuttonHi/Lolimitsettingand, Min.5minutes