Omnitron Systems Technology 4Tx specifications Model Type

Models: 4Tx

1 2
Download 2 pages 57.14 Kb
Page 2
Image 2
Model Type

Model Type

4Tx

 

 

Protocols

10BASE-T, 100BASE-TX

UTP Connectors

RJ-45

Controls

UTP X-over (Port 1), BP Enable,

Auto/Man, 10/100, FDX/HDX

 

 

 

LED Displays

Power, 10/100 UTP Link

Dimensions

W:0.85" x D:4.5" x H:2.8"

Weight

8 oz.

Compliance

UL, CE, FCC Class A

Power Requirement

0.9 @ 3.3VDC (typical)

Temperature

Standard:

0 to 50º C

Wide:

-40 to 60º C

 

Storage:

-40 to 80º C

Humidity

5 to 95% (non-condensing)

Altitude

-100m to 4000m

MTBF (hrs)

910, 000

 

 

 

Model Type

Connectors

Distance

 

 

 

8480-4

RJ-45 x 4

100m

 

 

 

For wide temperature (-40 to 60º C) modules, add a "W" to the end of the model number. Consult factory for other configurations and extended temperature (-40 to +75º C) modules.

Management is accomplished by using a Network Management Module (NMM) or a media converter with integrated management (such as an iConverter 10/100M2) that provides monitoring, remote configuration and trap notification. The management module can be accessed via SNMP, Telnet and via a serial port. The SNMP-based management is accomplished via Omnitron’s intuitive, graphic-oriented NetOutlook management software or third party SNMP management software, while the Telnet and the serial interfaces have an easy-to-use, menu-driven interface.

Some of the real-time 4Tx parameters that can be monitored include link and data receive status. Other parameters include module type and model, hardware and software revisions, serial numbers and a user-defined identifier.

The user can override the 4Tx module’s physical switch settings by using SNMP or Telnet to remotely configure switch-selectable parameters such as auto-negotiation, Half or Full-Duplex and Backplane Selection.

In addition to all standard iConverter SNMP traps such as module insertion and removal, the 4Tx modules can generate traps on port state changes including link-up and link-down. Trap monitoring of specific events can be selectively enabled or disabled by the network administrator.

Configuration

 

19-Module

 

 

5-Module

 

2-Module

1-Module

 

AC

24VDC

 

48VDC

AC

24VDC

48VDC

AC

18-60

US AC

Universal

 

 

VDC

AC

 

 

 

 

 

 

 

 

 

 

One (1) Power Supply

8200-1

8206-1

 

8205-1

8220-1

8226-1

8225-1

8230-0

8235-0

8240-1

8240-2

One (1) Power Supply

--

--

 

--

--

--

--

8230-1

8235-1

8241-1

8241-2

w/ Dying Gasp Support

 

 

 

 

 

 

 

 

 

 

 

 

Two (2) Power Supplies

8200-2

8206-2

 

8205-2

8220-2

8226-2

8225-2

--

--

8245-111*

8245-112*

Three (3) Power Supplies

8200-3

8206-3

 

8205-3

--

--

--

--

--

--

--

Spare Power Supply

8200-9

8206-9

 

8205-9

8220-9

8226-9

8225-9

--

--

--

--

23" Rack Mounting Kit

8091-2

8091-2

 

8091-2

8092-2

8092-2

8092-2

--

--

--

--

Blank Module Panel

8090-0

8090-0

 

8090-0

8090-0

8090-0

8090-0

8090-0

8090-0

--

--

Wall-Mounting Hardware Kit

--

--

 

--

--

--

--

8249-0

8249-0

8249-0

8249-0

DIN-Rail Mounting Kit

--

--

 

--

--

--

--

--

--

8250-0

8250-0

 

 

 

 

 

 

 

 

 

 

 

 

*Please refer to the iConverter 1-Module Redundant Power Chassis data sheet for additional model numbers and ordering options. For wide (-40 to +60º C) and extended (-40 to +75º C) temperature range chassis, contact Omnitron for details.

Trademarks are owned by their respective companies. iConverter is a registered trademark of Omnitron Systems Technology, Inc. NetOutlook is a trademark of Omnitron Systems Technology, Inc. Specifications subject to change without notice.

©2003-2007 Omnitron Systems Technology, Inc. All rights reserved.

091-18480-004E 9/07

800-675-8410949-250-6510www.omnitron-systems.cominfo@omnitron-systems.com • 140 Technology Dr. • Irvine, CA 92618