| Model Type | 4Tx |
| | |
| Protocols | 10BASE-T, 100BASE-TX |
| UTP Connectors | RJ-45 |
| Controls | UTP X-over (Port 1), BP Enable, |
| Auto/Man, 10/100, FDX/HDX |
| |
| | |
| LED Displays | Power, 10/100 UTP Link |
| Dimensions | W:0.85" x D:4.5" x H:2.8" |
| Weight | 8 oz. |
| Compliance | UL, CE, FCC Class A |
| Power Requirement | 0.9 @ 3.3VDC (typical) |
| Temperature | Standard: | 0 to 50º C |
| Wide: | -40 to 60º C |
| | Storage: | -40 to 80º C |
| Humidity | 5 to 95% (non-condensing) |
| Altitude | -100m to 4000m |
| MTBF (hrs) | 910, 000 |
| | | |
Model Type | Connectors | Distance |
| | |
8480-4 | RJ-45 x 4 | 100m |
| | |
For wide temperature (-40 to 60º C) modules, add a "W" to the end of the model number. Consult factory for other configurations and extended temperature (-40 to +75º C) modules.
Management is accomplished by using a Network Management Module (NMM) or a media converter with integrated management (such as an iConverter 10/100M2) that provides monitoring, remote configuration and trap notification. The management module can be accessed via SNMP, Telnet and via a serial port. The SNMP-based management is accomplished via Omnitron’s intuitive, graphic-oriented NetOutlook management software or third party SNMP management software, while the Telnet and the serial interfaces have an easy-to-use, menu-driven interface.
Some of the real-time 4Tx parameters that can be monitored include link and data receive status. Other parameters include module type and model, hardware and software revisions, serial numbers and a user-defined identifier.
The user can override the 4Tx module’s physical switch settings by using SNMP or Telnet to remotely configure switch-selectable parameters such as auto-negotiation, Half or Full-Duplex and Backplane Selection.
In addition to all standard iConverter SNMP traps such as module insertion and removal, the 4Tx modules can generate traps on port state changes including link-up and link-down. Trap monitoring of specific events can be selectively enabled or disabled by the network administrator.
Configuration | | 19-Module | | | 5-Module | | 2-Module | 1-Module |
| AC | 24VDC | | 48VDC | AC | 24VDC | 48VDC | AC | 18-60 | US AC | Universal |
| | VDC | AC |
| | | | | | | | | |
One (1) Power Supply | 8200-1 | 8206-1 | | 8205-1 | 8220-1 | 8226-1 | 8225-1 | 8230-0 | 8235-0 | 8240-1 | 8240-2 |
One (1) Power Supply | -- | -- | | -- | -- | -- | -- | 8230-1 | 8235-1 | 8241-1 | 8241-2 |
w/ Dying Gasp Support | |
| | | | | | | | | | |
Two (2) Power Supplies | 8200-2 | 8206-2 | | 8205-2 | 8220-2 | 8226-2 | 8225-2 | -- | -- | 8245-111* | 8245-112* |
Three (3) Power Supplies | 8200-3 | 8206-3 | | 8205-3 | -- | -- | -- | -- | -- | -- | -- |
Spare Power Supply | 8200-9 | 8206-9 | | 8205-9 | 8220-9 | 8226-9 | 8225-9 | -- | -- | -- | -- |
23" Rack Mounting Kit | 8091-2 | 8091-2 | | 8091-2 | 8092-2 | 8092-2 | 8092-2 | -- | -- | -- | -- |
Blank Module Panel | 8090-0 | 8090-0 | | 8090-0 | 8090-0 | 8090-0 | 8090-0 | 8090-0 | 8090-0 | -- | -- |
Wall-Mounting Hardware Kit | -- | -- | | -- | -- | -- | -- | 8249-0 | 8249-0 | 8249-0 | 8249-0 |
DIN-Rail Mounting Kit | -- | -- | | -- | -- | -- | -- | -- | -- | 8250-0 | 8250-0 |
| | | | | | | | | | | |
*Please refer to the iConverter 1-Module Redundant Power Chassis data sheet for additional model numbers and ordering options. For wide (-40 to +60º C) and extended (-40 to +75º C) temperature range chassis, contact Omnitron for details.
Trademarks are owned by their respective companies. iConverter is a registered trademark of Omnitron Systems Technology, Inc. NetOutlook is a trademark of Omnitron Systems Technology, Inc. Specifications subject to change without notice.
©2003-2007 Omnitron Systems Technology, Inc. All rights reserved.
091-18480-004E 9/07
800-675-8410 • 949-250-6510 • www.omnitron-systems.com • info@omnitron-systems.com • 140 Technology Dr. • Irvine, CA 92618