How to use the graph function
This monitor has the possibility to display the stored measurements as a graph. In order to get a clear history of your blood pressure the measurements are put in time zones:
•Morning: Measurements made between 0:00 and 9:59
•Daytime: Measurements made between 10:00 and 17:59
•Evening: Measurements made between 18:00 and 23:59
The last measurement in each time zone will be displayed. For example if you measure 3 times in the same time zone on the same day only the third reading will be displayed. On the other hand all read- ings will be stored in the memory (See also page 11).
There are three different graphs available:
Explanation of the graph display
When the GRAPH button is pushed the latest measurement will appear in a flashing display. In the example the measurement is made on January 31 at 22:40. The graph shows 140 mmHg for systolic and 95 mmHg for diastolic (top and bottom of vertical bar) and a pulse rate of 90 beats a minute.
Date of | Blood Pressure Values (sys- | English | |
tolic/diastolic) (mmHg) | |||
Measurement | |||
| |||
|
|
•All data graph: displays all measurements per week
•Morning data graph: displays all morning measurements per week
•Evening data graph: displays all evening measurements per week No graph display is provided for daytime data only.
To display the graph push the GRAPH CALL button.
All Data Graph is displayed.
|
| Pulse |
Month/Days of a Week | Rate | |
|
When you push the memory button in the graph display the details of the measurement will appear. Pushing the graph button again will bring you back the graph display. You can use ( ) the arrows in the graph and memory dis- play to leaf through the measurements.
Detail Screen of Data
in Flashing Display
All Data Graph
Push the GRAPH CALL button again to display the
Morning Data Graph.
Morning
Data
Mark
Morning Data Graph
The systolic blood pressure is higher than 170mmHg
When a systolic blood pressure above 170 mmHg is measured twice the ( ) symbol is displayed in the graph.
When a systolic blood pressure above 170 mmHg is measured three times the ( ) sym- bol disappears and the screen automatically changes to the “hypertension display”. The maximum displayed blood pressure value
Display screen where the | Graph Display Screen of |
systolic blood pressure | Hypertension Type |
values higher than 170 |
|
mmHg are measured |
|
twice |
|
Push the GRAPH CALL button again to display the
Evening Data Graph.
Night
• Each time you push the GRAPH CALL button, All, Data
How to change the settings
The settings of your OMRON 637IT blood pressure monitor can be changed according to your own preferences and comfort.
Morning, and Evening data are displayed in that
order repeatedly.
12
Mark
Night Data Graph
To enter the setting menu please press the SET button when your blood pressure monitor is switched
off. By using ( ) you can select your preference. By pressing the SET button again you lock your preference and proceed to the next item as shown in the figure. The on/off button (O/I) can be used to switch the monitor off again.
13