DATA-LINC GROUP

LCM100 User’s Guide

LCM100

Line Carrier Modem

Introduction

In the line carrier system, the hot line supplies current to connected loads and is also used as a carrier for data communication between modules. The Data-Linc LCM100 can communicate over the same line in a 240 volt single phase system or on any individual phase of a three-phase system.

Note: It will be necessary to have a signal coupler installed to ensure communications over different lines of the 240 volt, single phases system.

In the three-phase power environment, communication will occur freely if both devices are connected on the same phase, but cross-phase communication will require line conditioning by installation of a signal coupler between phases. As shown in Figure 1 below, two signal couplers are sufficient for all cross-plane combinations in a three-phase system. Installation of a signal coupler at the power distribution panel is fully described under the line conditioning section of this manual.

 

Hot

 

 

 

120V

signal coupler

Load

meter &

 

 

 

circuit

neutral

 

220V

breaker

 

 

 

 

120V

 

Load

 

Hot

 

 

Figure 1: Connecting a Signal Coupler, Single Phase System

The green wire is reference (earth) ground. It serves also as chassis ground and reduces equipment susceptibility to RF current, static discharge and interference from fluorescent lamps. The LCM100 system is designed to operate with a reference ground located at the power distribution panel. Reference ground is usually connected to the copy ground bus or to the distribution panel frame.

When the power cord is connected to a three-wire AC power outlet, the bottom round connector serves to ground the chassis, protecting against shock hazard, susceptibility to electro-magnetic interference and possible spurious emissions.