4.MAINTENANCE,TROUBLESHOOTING

WARNING

ELECTRICAL SHOCK HAZARD

Do not open the equipment.

Only qualified personnel should work inside the equipment.

4.1 Maintenance

Regular maintenance is important for good performance. Following the recommended maintenance procedures will help keep your set in good working condition.

4.1.1 General checking

Important points to be checked from time to time are tabulated below.

Maintenance check points

Check point

Action

Transducer cable

If conductors are exposed, replace cable.

Power cable plug/transducer cable plug

If loosened, tighten.

Display unit ground

.

 

If corroded, clean

Ship’s mains voltage

If out of ratings, correct problem.

4.1.2 Replacement of fuse

The fuse on the power cable protects the equipment against overvoltage/reverse polarity of the ship’s mains or internal fault of the equipment. If the fuse blows, find the cause before replacing the fuse. If the fuse blows again after replacement, call for service. A fuse rated for more than 3A should not be used since it would damage the equipment and void the warranty.

CAUTION

Use the proper fuse.

Use of a wrong fuse can cause fire or equipment damage.