RS-232 Protocol function list for EP737

RS-232 Protocol function list for EP737

Interface

3 wires RS-232C Protocol

Baud Rate : 19200

Data Bits: 8

Parity: None

Stop Bits: 1

Flow Control : None

Command Sequence

Write

Basic Protocol

Header :

‘*’

Address Code :

‘0’ fixed

Command Code :

ASCII Text

Data :

Fixed 3 digits

Terminator Code :

Carriage Return

Delimiter : Space

Carriage Return

Command Sequence

Read

Basic Protocol

 

 

Header

‘*’

Address Code

‘0’ fixed

Command Code

ASCII Text

Data

‘?’ fixed

Terminator Code

Carriage Return

Delimiter

Carriage Return

 

 

Acknowledgement

 

Basic Protocal

Receive OK

˝*000<CR>˝

Unknown Command

˝*255<CR>˝

Invalid Command

˝*001<CR>˝

In current source

 

Data value out of range

˝*002<CR>˝

Data response

As Write Command Format

Function List

 

Basic(Original)

Basic (Update)

Power On

IR 001

Didn’t support

Power Off

IR 002

 

Source PC

IR 003

Didn’t support

KeyStone

IR 004

 

Zoom

IR 005

 

Mute

IR 006

 

Freeze

IR 007

 

Menu

IR 008

 

Up

IR 009

 